Key result
Deep learning model estimates continuous arterial blood pressure from photoplethysmogram signals within ~5 mmHg error.
Why the study?
Continuous blood pressure monitoring typically requires invasive procedures due to non-invasive methods lacking accuracy, and existing methods rely on handcrafted feature computation limited to ideally shaped photoplethysmogram signals.
Does the PPG2ABP deep learning model accurately estimate continuous arterial blood pressure waveforms from non-invasive photoplethysmogram signals?
Does the PPG2ABP deep learning model accurately estimate continuous arterial blood pressure waveforms from non-invasive photoplethysmogram signals?
Answers are grounded in this paper and cite their sources.
The PPG2ABP algorithm demonstrates that deep learning can accurately translate non-invasive PPG signals into continuous arterial blood pressure waveforms, satisfying international clinical standards for DBP and MAP without requiring invasive catheterization or ECG inputs.
Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 ± 6.147 mmHg, 2.310 ± 4.437 mmHg, and 5.727 ± 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.
No takes yet. Share an insight, caveat, or question.
Ibtehaz et al. (2022) studied Continuous arterial blood pressure estimation (n=942). PPG2ABP deep learning pipeline vs. Ground truth invasive Arterial Blood Pressure (ABP) waveforms was evaluated on Mean Absolute Error (MAE) of the estimated continuous ABP waveform (MAE 4.604 mmHg). The PPG2ABP deep learning model successfully estimated continuous arterial blood pressure waveforms from photoplethysmogram signals with a mean absolute error of 4.604 mmHg.