Key result
The proposed SMP-Net framework for non-contact multi-physiological signal estimation achieved a mean absolute error of 1.12 bpm for heart rate estimation on the MMVS dataset.
Why the study?
Most existing rPPG methods use only one data modality and output a single type of physiological signal at a time.
The proposed SMP-Net framework enables accurate, continuous, non-contact estimation of multiple physiological signals using visible and infrared facial video fusion.
Multi-modal rPPG enables simultaneous vital-sign estimation from video; leaves open clinical validation before cardiovascular use.
Heart rate (HR), heart rate variability (HRV), and respiratory rate (RR) are vital physiological signals that can reveal the physiological and psychological states of human beings. Recent research studies have demonstrated that these physiological signals can be estimated in a non-contact way from visible or infrared facial videos based on remote Photoplethysmography (rPPG). However, most existing methods only use only one data modality and output a single type of physiological signal at a time. To overcome these restrictions, we propose a multi-task framework named the SMP-Net based on multimodal fusion to realize the non-contact multi-physiological signals estimation. First, a joint attention feature fusion (JAFF) module is designed to encode and fuse features from visible and infrared videos. The JAFF module considers different modality-wise, spatial, and channel-wise information on features comprehensively. Then, a task-oriented feature refinement (TOFR) module is developed to extract task-oriented features by refining shared features to improve the estimation performance. Finally, the proposed SMP-Net is validated on the MMVS, VIPL-HR, and UBFC-rPPG datasets and outperforms state-of-the-art methods. Our proposed SMP-Net achieves 1.12 bpm mean absolute error (MAE) for HR estimation, 0.58 ρ for rPPG estimation, and 2.08 MAE for RR estimation on the MMVS dataset. On the VIPL-HR and UBFC-rPPG datasets, the MAE of HR estimation is 2.03 and 0.59 bpm, respectively. The proposed SMP-Net is of great significance for continuous non-contact estimation of multi-physiological signals.
No takes yet. Share an insight, caveat, or question.
Ding et al. (2022) studied this question. SMP-Net (multi-task framework based on multimodal fusion) vs. state-of-the-art methods was evaluated on Heart rate estimation mean absolute error (MAE) on the MMVS dataset. The proposed SMP-Net framework for non-contact multi-physiological signal estimation achieved a mean absolute error of 1.12 bpm for heart rate estimation on the MMVS dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: