Key result
A patient-specific biomechanical model accurately simulated mean aortic pressure with a mean difference of -0.9 mmHg compared to invasive measurements, demonstrating statistical equivalence (p<0.001).
Why the study?
Direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations during general anesthesia.
Can patient-specific biomechanical models accurately estimate cardiovascular functional indicators during general anesthesia?
Observational (n=45)
No
Can patient-specific biomechanical models accurately estimate cardiovascular functional indicators during general anesthesia?
Patient-specific biomechanical models can accurately simulate cardiovascular hemodynamics and track changes in functional indicators like ventricular-arterial coupling during general anesthesia.
Answers are grounded in this paper and cite their sources.
May support non-invasive hemodynamic monitoring under anesthesia; leaves open prospective outcome validation.
During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (Vva), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased Vva (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, Vva increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology.
No takes yet. Share an insight, caveat, or question.
Gall et al. (2020) conducted an observational in General anesthesia for intracranial endovascular procedure (n=45). Patient-specific biomechanical model simulation vs. Invasive clinical measurements was evaluated on Mean difference between simulated and measured mean aortic pressure (MAP) (MD -0.9 mmHg, 95% CI -1.7 to -0.1, p=<0.001). A patient-specific biomechanical model accurately simulated mean aortic pressure with a mean difference of -0.9 mmHg compared to invasive measurements, demonstrating statistical equivalence (p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: