Key result
Transthoracic and transesophageal echocardiography demonstrated limited accuracy for detecting acute pulmonary embolism compared to helical CT, with a combined sensitivity of 59% and specificity of 77%.
Why the study?
Does transthoracic and transesophageal echocardiography accurately detect acute pulmonary embolism compared to helical CT in patients with suspected acute pulmonary embolism?
Cross-Sectional (n=35)
Does transthoracic and transesophageal echocardiography accurately detect acute pulmonary embolism compared to helical CT in patients with suspected acute pulmonary embolism?
Transthoracic and transesophageal echocardiography have limited overall accuracy for detecting acute pulmonary embolism compared to helical CT, though accuracy is higher for central PE.
Echocardiography should not yet guide acute PE diagnosis; leaves open its adjunctive role in central emboli pending prospective trials.
OBJECTIVE: The goal of this study was to prospectively compare the accuracy of transthoracic and transesophageal B-mode and Doppler echocardiography with helical CT for detecting acute pulmonary embolism. SUBJECTS AND METHODS: Thirty-five consecutive patients underwent transthoracic and transesophageal echocardiography and contrast-enhanced helical CT. Echocardiographic examinations were analyzed for indirect criteria, including increased main pulmonary artery diameter, tricuspid regurgitation, and dilatation of the right ventricular cavity, as well as for direct thrombus visualization. Sensitivity, specificity, and negative and positive predictive values were calculated. RESULTS: Pulmonary embolism was revealed by helical CT in 22 of 35 patients; in 11 of these 22 cases, central pulmonary embolism was seen. Transthoracic and transesophageal B-mode echocardiography failed to reveal pulmonary embolism in nine patients, two of whom had central pulmonary embolism. The sensitivity and specificity of the combination of both echocardiographic investigations were 59% and 77% respectively (82% and 92% for central pulmonary embolism). In three patients, pulmonary embolism was diagnosed by direct clot detection with transesophageal echocardiography. In two patients, only the indirect parameters indicated pulmonary embolism. Overall indirect echocardiographic parameters were characterized by a low sensitivity that ranged from 50% for tricuspid regurgitation to 21% for main pulmonary artery diameter. CONCLUSION: In comparison with helical CT, transthoracic and transesophageal echocardiography had limited accuracy for detecting pulmonary embolism.
No takes yet. Share an insight, caveat, or question.
Steiner et al. (1996) conducted a cross-sectional in Acute pulmonary embolism (n=35). Transthoracic and transesophageal echocardiography vs. Helical CT was evaluated on Detection of acute pulmonary embolism. Transthoracic and transesophageal echocardiography demonstrated limited accuracy for detecting acute pulmonary embolism compared to helical CT, with a combined sensitivity of 59% and specificity of 77%.