Answers are grounded in this paper and cite their sources.
Investigates thermoregulatory responses during running, suggesting running economy is critical for performance.
We sought to determine the independent influence of running economy (RE) and aerobic fitness [maximum oxygen consumption (V̇O 2max)] on thermoregulatory responses during treadmill running by conducting two studies. In study 1, seven high (HI-FIT: 61 ± 5 ml O2 · kg(-1) · min(-1)) and seven low (LO-FIT: 45 ± 4 ml O2 · kg(-1) · min(-1)) V̇O 2max males matched for physical characteristics and RE (HI-FIT: 200 ± 21; LO-FIT: 200 ± 18 ml O2 · kg(-1) · km(-1)) ran for 60 min at 1) 60%V̇O 2max and 2) a fixed metabolic heat production (Hprod) of 640 W. In study 2, seven high (HI-ECO: 189 ± 15.3 ml O2 · kg(-1) · km(-1)) and seven low (LO-ECO: 222 ± 10 ml O2 · kg(-1) · km(-1)) RE males matched for physical characteristics and V̇O 2max (HI-ECO: 60 ± 3; LO-ECO: 61 ± 7 ml O2 · kg(-1) · min(-1)) ran for 60 min at a fixed 1) speed of 10.5 km/h and 2) Hprod of 640 W. Environmental conditions were 25.4 ± 0.8°C, 37 ± 12% RH. In study 1, at Hprod of 640 W, similar changes in esophageal temperature (ΔTes; HI-FIT: 0.63 ± 0.20; LO-FIT: 0.63 ± 0.22°C; P = 0.986) and whole body sweat losses (WBSL; HI-FIT: 498 ± 66; LO-FIT: 497 ± 149 g; P = 0.984) occurred despite different relative intensities (HI-FIT: 55 ± 6; LO-FIT: 39 ± 2% V̇O 2max; P < 0.001). At 60% V̇O 2max, ΔTes (P = 0.029) and WBSL (P = 0.003) were greater in HI-FIT (1.14 ± 0.32°C; 858 ± 130 g) compared with LO-FIT (0.73 ± 0.34°C; 609 ± 123 g), as was Hprod (HI-FIT: 12.6 ± 0.9; LO-FIT: 9.4 ± 1.0 W/kg; P < 0.001) and the evaporative heat balance requirement (Ereq; HI-FIT: 691 ± 74; LO-FIT: 523 ± 65 W; P < 0.001). Similar sweating onset ΔTes and thermosensitivities occurred between V̇O 2max groups. In study 2, at 10.5 km/h, ΔTes (1.16 ± 0.31 vs. 0.78 ± 0.28°C; P = 0.017) and WBSL (835 ± 73 vs. 667 ± 139 g; P = 0.015) were greater in LO-ECO, as was Hprod (13.5 ± 0.6 vs. 11.3 ± 0.8 W/kg; P < 0.001) and Ereq (741 ± 89 vs. 532 ± 130 W; P = 0.007). At Hprod of 640 W, ΔTes (P = 0.910) and WBSL (P = 0.710) were similar between HI-ECO (0.55 ± 0.31°C; 501 ± 88 g) and LO-ECO (0.57 ± 0.16°C; 483 ± 88 g), but running speed was different (HI-ECO: 8.2 ± 0.6; LO-ECO: 7.2 ± 0.4 km/h; P = 0.025). In conclusion, thermoregulatory responses during treadmill running are not altered by V̇O 2max, but by RE because of differences in Hprod and Ereq.
No takes yet. Share an insight, caveat, or question.
Smoljanić et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: