Key result
Quantitative DECT perfusion analysis improves myocardial ischemia detection with ~0.92 AUC versus visual reading.
Observational (n=43)
Effect estimate: AUC 0.921 (95% CI 0.860-0.981)
Absolute Event Rate: 0.921% vs 0.685%
p-value: p=<0.05
Evaluates quantitative iodine measurement accuracy in myocardial ischemia, suggesting improved analysis methods.
PURPOSE: Dual-energy computed tomography (DECT) can be used for visual determination of iodine distribution in the myocardium (iodine image); however, the accuracy and reproducibility of the process remains debatable. Because of the low contrast-to-noise ratio of CT, we hypothesized that quantitative measurement may be more accurate for detecting myocardial ischemia. In this study, we evaluated our quantitative method by comparing it with visual analysis using Tc-tetrofosmin (TF) stress-rest single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) as the reference standard. MATERIALS AND METHODS: Forty-three patients who had a significant stenosis on cardiac rest DECT and had received Tc-TF stress-rest SPECT MPI within 1 month were retrospectively analyzed. The regions of interest were set on iodine images in accordance with the American Heart Association (AHA) 17-segment model (a total of 731 segments). The regions of interest values were divided by the amount of iodine (mg) per unit weight (kg) and defined as perfusion value (perfusion value analysis). All segments were also visually analyzed and receiver operating characteristic curve analysis performed to identify the superior analysis. RESULTS: The receiver operating characteristic curve analysis showed that perfusion value analysis is significantly superior to visual analysis [the area under the curve: 0.921 (95% confidence interval, 0.860-0.981) versus 0.685 (95% confidence interval, 0.580-0.791), respectively, P<0.05], with 93.8% sensitivity, 99.1% specificity, 98.9% accuracy, 83.3% positive predictive value, and 99.7% negative predictive value (P<0.01). CONCLUSIONS: Quantitative analysis of the iodine image of rest DECT, called perfusion value analysis, is more accurate than visual analysis when compared with Tc-TF SPECT MPI as the reference standard.
No takes yet. Share an insight, caveat, or question.
Nakahara et al. (2017) conducted an observational in Myocardial ischemia (n=43). Quantitative perfusion value analysis of rest DECT iodine image vs. Visual analysis of rest DECT iodine image was evaluated on Detection of myocardial ischemia evaluated by area under the curve (AUC) (AUC 0.921, 95% CI 0.860-0.981, p=<0.05). Quantitative perfusion value analysis of rest DECT iodine images was significantly superior to visual analysis for detecting myocardial ischemia (AUC 0.921 vs 0.685; P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: