Key result
Atrial fibrillation impaired the diagnostic accuracy of myocardial perfusion imaging for detecting significant CAD during exercise stress testing (P=0.039), but not during vasodilator stress (P=0.664).
Why the study?
Does the presence of atrial fibrillation affect the diagnostic accuracy of myocardial perfusion imaging for detecting significant coronary artery disease?
Case-Control (n=222)
Does the presence of atrial fibrillation affect the diagnostic accuracy of myocardial perfusion imaging for detecting significant coronary artery disease?
Absolute Event Rate: 0.71% vs 0.8%
p-value: p=0.212
The presence of atrial fibrillation impairs the diagnostic accuracy of exercise stress myocardial perfusion imaging for detecting significant CAD, but vasodilator stress imaging remains accurate.
AF impairs exercise MPI accuracy for significant CAD; leaves open need for prospective validation of pharmacologic protocols.
BACKGROUND: To evaluate the accuracy of myocardial perfusion imaging (MPI) on a novel cadmium-zinc-thelluride camera in detecting significant coronary artery disease (CAD) in patients with atrial fibrillation (AF). METHODS AND RESULTS: Seventy-four subjects with AF submitted to stress-rest MPI and coronary angiography were consecutively enrolled. One hundred and forty-eight patients in sinus rhythm, matched for age, sex, and type of stress-test protocol and with known coronary anatomy served as controls. The summed difference score, as measure of reversible myocardial ischaemia, was calculated. A coronary stenosis ≥70% was considered significant. The prevalence of significant CAD did not differ between AF patients and controls. At receiving operating characteristic analysis MPI showed relevant accuracy in unmasking the presence of significant CAD both in AF and in control patients (areas under the curve 0.71 vs. 0.80, P for difference: 0.212). However, after stratifying patients according to the stress protocol, a significant interaction between the presence of AF and MPI diagnostic power was evident. While in the case of a vasodilator stress-test MPI diagnostic accuracy remained high in both groups of patients (P for difference: 0.664), in those submitted to an exercise stress-test the diagnostic power of MPI was significantly lower in the presence of AF (P for difference: 0.039), because of a lower specificity. Interestingly, at multivariate analysis, a lower exercise duration (P = 0.017) was the major predictor of reduced MPI specificity. CONCLUSION: The presence of AF impairs MPI accuracy on the detection significant CAD. This effect was only apparent in the case of an exercise stress-test, while disappeared in patients submitted to vasodilator stress.
No takes yet. Share an insight, caveat, or question.
Gimelli et al. (2015) conducted a case-control in Atrial fibrillation (n=222). Atrial fibrillation vs. Sinus rhythm was evaluated on Accuracy of myocardial perfusion imaging in detecting significant coronary artery disease (Area Under the Curve) (p=0.212). Atrial fibrillation impaired the diagnostic accuracy of myocardial perfusion imaging for detecting significant CAD during exercise stress testing (P=0.039), but not during vasodilator stress (P=0.664).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: