Answers are grounded in this paper and cite their sources.
Aerobic capacity (VO2peak ) testing equipment can be expensive. Garmin fitness watches are significantly cheaper, and Garmin has developed a fitness test that estimates VO 2peak . The purpose of this study was to validate the Garmin fitness test, using a Garmin Forerunner 920XT fitness watch, against VO 2peak measurement, using a Parvomedics TrueOne 2400 open circuit spirometry device. Sixteen college students (10 male and 6 female) volunteered to complete the Garmin fitness test followed several days later by a Bruce treadmill test while oxygen consumption was measured via open circuit spirometry. The average VO 2peak from the Garmin test was 45.4 (± 5.6) ml/kg/min, compared to 45.0 (± 8.9) ml/kg /min from open circuit spirometry. There were no significant differences between the measurements (t = 0.221 with p = 0.828). The two measurements were highly correlated with a correlation coefficient of 0.84 (p =0.000). The Garmin fitness test seems to be a highly accurate estimation of VO 2peak2peak.
No takes yet. Share an insight, caveat, or question.
Kraft et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: