BACKGROUND: Interquartile range/median value (IQR/M) of liver stiffness measurement (LSM) is a factor in chronic hepatitis C (CHC) leading to over estimation of fibrosis by Fibroscan. AIM: To investigate factors that affect the accuracy of LSM in chronic hepatitis B (CHB). METHODS: One hundred and ninety-nine patients were enrolled. Only procedures yielding > or =10 valid measurements were considered reliable. Liver fibrosis was evaluated using the Batts and Ludwig system. Liver biopsy (LB) specimens <15 mm were considered ineligible. RESULTS: The mean age (142 men and 57 women) was 40.1 years. A significant discordance (discordance of at least two stages between LB and LSM) was identified in 38 (19.1%) and 47 (23.6%) patients respectively, according to Marcellin et al. and Chan et al.'s cutoff values. In multivariate analyses, BMI and fibrosis stage (F0-2 vs. F3-4) were identified as independent predictors for significant discordance (P = 0.040; hazard ratio [HR], 1.126; 95% confidence interval [CI], 1.005-1.261 and P = 0.036; HR, 0.450; 95% CI, 0.213-0.949 respectively) with Marcellin et al.'s cutoffs, whereas fibrosis stage was the only independent predictor (P = 0.004; HR, 0.300; 95% CI, 0.131-0.685) with Chan's cutoffs. CONCLUSIONS: Success rate and IQR/M were not predictive factors of the accuracy for diagnosing liver fibrosis by Fibroscan in CHB. Fibrosis stage (F0-2) was the only factor to predict significant discordance between LB and LSM.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: