Key result
Higher nadir temperature during left superior pulmonary vein freezing was associated with a two times greater width of acute left atrial ridge lesions.
Why the study?
Acute left atrial ridge lesions had not been quantitatively evaluated and their influence on combined cryoballoon ablation and left atrial appendage closure remained to be explored.
Does cryoballoon ablation cause acute left atrial ridge lesions that affect left atrial appendage closure in patients with nonvalvular atrial fibrillation?
Observational (n=117)
Does cryoballoon ablation cause acute left atrial ridge lesions that affect left atrial appendage closure in patients with nonvalvular atrial fibrillation?
Acute left atrial ridge lesions frequently occur after cryoballoon ablation and affect the measurement of pacifier devices for left atrial appendage closure, but have little impact on occluder devices.
Answers are grounded in this paper and cite their sources.
Acute ridge lesions may alter pacifier device sizing for left atrial appendage closure; leaves open whether temperature optimization affects outcomes.
BACKGROUND: Acute left atrial ridge (LAR) lesions have been observed following atrial fibrillation (AF) ablation. However, LAR lesions had not yet been quantitatively evaluated and their influence on procedure combining cryoballoon (CB) ablation with left atrial appendage closure (LAAC) remained to be explored. METHODS: The profile of LAR lesions was measured by transesophageal echocardiography (TEE) in 117 consecutive nonvalvular AF patients, who underwent the combined procedure of CB ablation and LAAC. We thoroughly investigated how LAR lesions correlated with baseline variables and clinical outcomes. RESULTS: A total of 95 out of 96 available TEE images presented prominent acute LAR lesions. In terms of dimensions, there was a greater change in width (Δwidth = 3.6 ± 2.3 mm) than the thickness (Δthickness = 2.6 ± 3.5 mm), and the outer ostium was narrowed (Δouter ostium diameter = -3.4 ± 4.0 mm), while the inner ostium remained unchanged. A higher nadir temperature when freezing the left superior pulmonary vein (LSPV) led to an LAR lesion with a two times greater width (adjusted odds ratio = 1.16; 95% confidence interval, 1.02-1.31). In the evaluation of LAAC outcomes, four patients implanted with Watchman devices had minimal residual flow at the inferior border, while two implanted with LAmbre devices developed residual flow at the LAR side. Clinical outcomes were similar between groups divided by lesion size. CONCLUSION: Acute LAR lesions frequently occurred following the CB ablation combined procedure, and lesion width positively correlates with LSPV nadir temperature. The presence of these lesions affects the measurement of pacifier devices but has little impact on that of occluder devices.
No takes yet. Share an insight, caveat, or question.
Ren et al. (2020) conducted an observational in Nonvalvular atrial fibrillation (n=117). Higher nadir temperature during left superior pulmonary vein freezing was evaluated on Left atrial ridge lesion with a two times greater width (adjusted OR 1.16, 95% CI 1.02-1.31). Higher nadir temperature during left superior pulmonary vein freezing was associated with a two times greater width of acute left atrial ridge lesions.
Synapse has enriched 10 related papers. Consider them for comparative context: