Key result
Myocardial contrast echocardiography during balloon inflation demonstrated a functional border zone of 13 +/- 4 mm (short-axis) and 16 +/- 9 mm (long-axis) in patients with effort angina.
Why the study?
Does myocardial contrast echocardiography demonstrate the existence of a functional border zone in human hearts during coronary occlusion?
Observational (n=13)
Does myocardial contrast echocardiography demonstrate the existence of a functional border zone in human hearts during coronary occlusion?
Myocardial contrast echocardiography demonstrates the existence of a functional border zone of nonischemic contractile dysfunction in human hearts during coronary occlusion, which may confound wall motion analysis for assessing ischemic area.
Answers are grounded in this paper and cite their sources.
FBZ detection in humans may confound wall-motion interpretation during ischemia; leaves open its clinical impact pending larger studies.
BACKGROUND: Although the presence of a functional border zone (FBZ), defined as the nonischemic but asynergic myocardium adjacent to the ischemic area, has been demonstrated in animal hearts, it is not known whether this zone exists in humans. METHODS AND RESULTS: Myocardial contrast echocardiography (MCE) was performed before and during balloon inflation in the area of coronary stenosis by injecting contrast medium through the guiding catheter in 13 patients with effort angina who underwent successful coronary angioplasty. The area showing MCE defect during balloon inflation was determined with reference to the preangioplasty MCE and was regarded as an ischemic area. The size of the FBZ was assessed by measuring the length of the endocardium that showed asynergy in the echo-enhanced (nonischemic) area. The FBZ measured was 13 +/- 4 mm in the short-axis view (n = 5) and 16 +/- 9 mm in the long-axis view (n = 8). CONCLUSIONS: Nonischemic contractile dysfunction exists even in human hearts. The presence of an FBZ may limit the use of wall motion analysis in assessing the risk or ischemic area in patients with myocardial infarction. MCE appears to be a unique technique for assessing the risk or ischemic area.
No takes yet. Share an insight, caveat, or question.
Nanto et al. (1993) conducted an observational in Effort angina (n=13). Myocardial contrast echocardiography during balloon inflation vs. Preangioplasty myocardial contrast echocardiography was evaluated on Size of the functional border zone (FBZ). Myocardial contrast echocardiography during balloon inflation demonstrated a functional border zone of 13 +/- 4 mm (short-axis) and 16 +/- 9 mm (long-axis) in patients with effort angina.
Synapse has enriched 10 related papers. Consider them for comparative context: