Demonstrates voltage degradation prediction in PEMFCs, suggesting improved health management.
Accurate voltage degradation prediction is essential for health management and lifetime extension of proton exchange membrane fuel cell (PEMFC) systems. During long-term constant-current operation, stack voltage evolves nonlinearly and is influenced by coupled variations in temperature, pressure, flow rate, and humidity, while many deep learning-based models lack physical interpretability. This study proposes an interpretable Transformer-based framework for PEMFC voltage degradation prediction under constant-current operation. The framework integrates outlier correction, interpolation, Savitzky–Golay filtering, Z-score normalization, sliding-window reconstruction, Transformer-based prediction, and feature-ablation interpretation. Using multivariate sensor measurements and historical voltage as inputs, the Transformer was compared with RNN, LSTM, and GRU baselines under identical preprocessing and evaluation conditions. The models were evaluated chronologically by continuously applying the sliding-window model over the held-out final 20% of the aging sequence. The Transformer achieved the best performance, with MAE of 8.2 × 10−4, RMSE of 1.18 × 10−3, MAPE of 0.0256%, and R2 of 0.9961. Compared with the second-best RNN model, it reduced MAE, RMSE, and MAPE by 9.89%, 7.81%, and 9.86%, respectively. Feature ablation showed that flow- and pressure-related variables contributed 50.08% and 26.78% of the total importance, respectively.
No takes yet. Share an insight, caveat, or question.
Yi et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: