Periaortic fat tissue volume measured in contrast-enhanced CT-angiographies showed excellent correlation (r=0.995) with unenhanced scans, despite a consistent underestimation of about 10%.
Why the study?
The feasibility of quantifying abdominal periaortic fat tissue in enhanced CT angiographies compared with unenhanced CT scans, along with methodological issues affecting clinical implementation, was unclear.
Can periaortic fat tissue be reliably quantified in contrast-enhanced CT angiography compared to unenhanced CT scans?
Observational (n=148)
No
Can periaortic fat tissue be reliably quantified in contrast-enhanced CT angiography compared to unenhanced CT scans?
Effect estimate: r = 0.995 (95% CI 0.993-0.997)
p-value: p=<0.0001
Periaortic fat tissue can be reliably quantified in contrast-enhanced CT angiographies, with volume slightly underestimated by about 10% compared to unenhanced scans.
Enables periaortic fat quantification on routine contrast CT with correction; leaves open prospective validation before clinical adoption.
To examine the feasibility of the quantification of abdominal periaortic fat tissue (PaFT) (tissue within - 45 to - 195 HU) in enhanced CT-angiographies compared to unenhanced CT-scans and identify methodological issues affecting its clinical implementation. Using OsirixMD, PaFT volume and mean HU value were retrospectively measured within a 5 mm periaortic ring in paired unenhanced and enhanced abdominal aortic CT-scans. The correlation between PaFT values was examined in a derivation cohort (n = 101) and linear regression analysis produced correction factors to convert values from enhanced into values from unenhanced CTs. The conversion factors were then applied to enhanced CTs in a different validation cohort (n = 47) and agreement of corrected enhanced values with values from unenhanced scans was evaluated. Correlation between PaFT Volume und Mean HU from enhanced and unenhanced scans was very high (r > 0.99 and r = 0.95, respectively, p < 0.0001 for both). The correction factors for PaFT Volume and Mean HU were 1.1057 and 1.0011. Potential confounding factors (CT-kilovoltage, slice thickness, mean intraluminal contrast density, aortic wall calcification, longitudinal variation of intraluminal contrast density, aortic diameter) showed no significant effect in a multivariate regression analysis (p > 0.05). Bland-Altman analysis of corrected enhanced and unenhanced values showed excellent agreement and Passing-Bablok regression confirmed minimal/no residual bias. PaFT can be quantified in enhanced CT-angiographies very reliably. PaFT Volume scores are very consistently slightly underestimated in enhanced scans by about 10%, while the PaFT Mean HU value remains practically constant and offers distinct methodological advantages. However, a number of methodological issues remain to be addressed.
No takes yet. Share an insight, caveat, or question.
Mamopoulos et al. (2022) conducted an observational in Abdominal aortic aneurysm and non-aneurysmatic aorta (n=148). Contrast-enhanced CT angiography vs. Unenhanced CT scans was evaluated on Correlation of periaortic fat tissue (PaFT) volume between enhanced and unenhanced CT scans (r = 0.995, 95% CI 0.993-0.997, p=<0.0001). Periaortic fat tissue volume measured in contrast-enhanced CT-angiographies showed excellent correlation (r=0.995) with unenhanced scans, despite a consistent underestimation of about 10%.