Two procedures to introduce a lithium metal reference electrode into commercially manufactured lithium-ion pouch cells (Kokam SLPB 533459H4) are described and compared. By introducing a stable reference potential, the individual behavior of the positive and negative electrodes can be studied in operando under normal cycling. Unmodified cells and half-cells made from harvested electrode material were cycled under identical conditions to the modified cells to compare capacity degradation during cycling and thus validate each modification procedure for degradation testing. A configuration that did not affect the performance of the cell over 20 cycles was successfully developed.
No takes yet. Share an insight, caveat, or question.
McTurk et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: