Key result
Seal-leak currents substantially alter action potential morphology in hiPSC-CMs even at resistances above 1 GΩ.
Why the study?
The contribution of seal-leak current to the immature and heterogeneous phenotype of iPSC-CMs has been overlooked in foundational studies and computational models, prompting this evaluation of its effect on action potential morphology recordings.
Seal-leak current is a major confounding experimental artifact in iPSC-CM patch clamp studies, even under ideal experimental conditions, and requires careful measurement and mathematical compensation.
Answers are grounded in this paper and cite their sources.
May bias iPSC-CM data informing arrhythmia therapies; leaves open need for routine seal-leak compensation in patch-clamp studies.
AIMS: Human-induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) have become an essential tool to study arrhythmia mechanisms. Much of the foundational work on these cells, as well as the computational models built from the resultant data, has overlooked the contribution of seal-leak current on the immature and heterogeneous phenotype that has come to define these cells. The aim of this study is to understand the effect of seal-leak current on recordings of action potential (AP) morphology. METHODS AND RESULTS: Action potentials were recorded in human iPSC-CMs using patch clamp and simulated using previously published mathematical models. Our in silico and in vitro studies demonstrate how seal-leak current depolarizes APs, substantially affecting their morphology, even with seal resistances (Rseal) above 1 GΩ. We show that compensation of this leak current is difficult due to challenges with obtaining accurate measures of Rseal during an experiment. Using simulation, we show that Rseal measures (i) change during an experiment, invalidating the use of pre-rupture values, and (ii) are polluted by the presence of transmembrane currents at every voltage. Finally, we posit that the background sodium current in baseline iPSC-CM models imitates the effects of seal-leak current and is increased to a level that masks the effects of seal-leak current on iPSC-CMs. CONCLUSION: Based on these findings, we make recommendations to improve iPSC-CM AP data acquisition, interpretation, and model-building. Taking these recommendations into account will improve our understanding of iPSC-CM physiology and the descriptive ability of models built from such data.
No takes yet. Share an insight, caveat, or question.
Clark et al. (2023) studied Human-induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) in patch clamp experiments (n=37). Seal-leak current vs. Baseline (leak-free) simulations or pre-rupture measurements was evaluated on Action potential (AP) morphology, including minimum potential, maximum upstroke velocity, action potential duration, and cycle length. Seal-leak current depolarizes action potentials and substantially alters their morphology in human-induced pluripotent stem cell-derived cardiomyocytes, even with seal resistances above 1 GΩ.
Synapse has enriched 10 related papers. Consider them for comparative context: