Key result
Spline-based denoising of dynamic MR spectroscopy data was the most effective technique, reducing root mean square error by 70% compared to unprocessed noisy data.
Why the study?
MR spectroscopy of dynamic systems is limited by low signal to noise, and comparing denoising methods along a series of spectra may identify techniques to reduce metabolite peak fitting errors.
Effect estimate: 70% reduction
Spline-based indirect time domain denoising substantially improves metabolite fitting accuracy in dynamic MR spectroscopy compared to unprocessed data.
Spline denoising substantially improves metabolite fitting in dynamic MRS; leaves open optimal use in cardiac applications.
Purpose MR spectroscopy of dynamic systems is limited by low signal to noise. Denoising along a series of acquired spectra exploits their temporal correlation to improve the quality of individual spectra, and reduce errors in fitting metabolite peaks. In this study we compare the performance of several denoising methods. Methods Six different denoising methods were considered: SIFT (Spectral Improvement by Fourier Thresholding), HSVD (Hankel Singular Value Decomposition), spline, wavelet, sliding window and sliding Gaussian. Pseudo-synthetic data was constructed to mimic 31 Phosphorus spectra from exercising muscle. For each method the optimal tuning parameters were determined for SNRs of 2, 5, 10 and 20 using a Monte Carlo approach. Denoised data from each method was then fitted using the AMARES algorithm and the results compared to the pseudo-synthetic ground truth. Results All six methods produced improvements in both fitting accuracy and agreement with the ground truth, compared to unprocessed noisy data. The least effective methods, SIFT and HSVD, achieved around 10-20% reduction in RMS error, while the most effective, Spline, reduced RMS error by 70%. The improvement from denoising was typically greater for lower SNR data. Conclusions Indirect time domain denoising of dynamic MR spectroscopy data can substantially improve subsequent metabolite fitting. Spline-based denoising was found to be the most flexible and effective technique.
No takes yet. Share an insight, caveat, or question.
Rowland et al. (2021) studied None (Methodological study using MRS data) (n=4). Indirect time domain denoising methods (specifically Spline-based denoising) vs. Unprocessed noisy data was evaluated on Root Mean Square Error (RMSE) between estimated metabolite concentrations and ground truth (70% reduction). Spline-based denoising of dynamic MR spectroscopy data was the most effective technique, reducing root mean square error by 70% compared to unprocessed noisy data.
Synapse has enriched one closely related paper. Consider it for comparative context: