Key result
In patients with acute type A aortic dissection treated with the transapical aortic cannulation technique, the overall mortality rate was 9.38%.
Cohort (n=309)
No
Transapical aortic cannulation for acute type A aortic dissection is associated with a 9.38% 60-day mortality rate, with coronary artery disease and preoperative hemodynamic deterioration identified as major risk factors.
Answers are grounded in this paper and cite their sources.
May support transapical cannulation in acute type A dissection; leaves open need for comparative trials before practice change.
OBJECTIVE: The aim of this study was to show a technique and the results of 60-day survival rate under treatment of Acute Type A Aortic Dissection by Transapical Aortic Cannulation Technique.MATERIAL AND METHODS: The data has been investigated through 12 years surgery experience since June 2003 in Acute Type A Acute Aortic Dissection by Transapical Aortic Cannulation Technique. This study was approved and reviewed by the ethical committee of the Kawasaki Saiwai Hospital, Kawasaki, Japan. Statistical Analysis: Cox proportional hazard regression was employed to analyze risk ratio, and Kaplan Meier curve was used to estimate the survival time. Statistically were significant at p < 0.05.RESULTS: The study population (n =309) was investigated for survival analysis. The person-time was 6363.50 person/months. We found that, the death outcome was 29 persons (9.38%). The mortality rate was 4.55/1000 person/months (95% Confidence Interval = 3.17-6.56/1000 person-month)CONCLUSION: Risk factors influencing the survival rate in Acute Type A Aortic Dissection included Coronary Artery Disease, Preoperative Hemodynamic Deterioration, Total Arch Replacement, cardiopulmonary bypass technique using only Deep Hypothermic Circulatory Arrest, Deep Hypothermic Circulatory Arrest with Retrograde Cerebral Perfusion and Deep Hypothermic Circulatory Arrest with Antegrade Selective Cerebral Perfusion. The enlargement of Ascending Aortic diameter and Proximal Descending Aorta diameter increased the death rate by 11% and 18%, respectively. Each time the diameter expanded 1 mm, and the operation time extended 1 minute, the death rate was increased by 1%.
No takes yet. Share an insight, caveat, or question.
Saraithong et al. (2017) conducted a cohort in Acute type A aortic dissection (n=309). Transapical aortic cannulation technique was evaluated on Mortality rate (95% CI 3.17-6.56). In patients with acute type A aortic dissection treated with the transapical aortic cannulation technique, the overall mortality rate was 9.38%.
Synapse has enriched 10 related papers. Consider them for comparative context: