Key result
A bionic baroreflex system attenuated the decrease in arterial pressure following thigh tourniquet deflation to 1+/-2 mm Hg at 50 seconds, compared to 25+/-2 mm Hg without the system.
Why the study?
Does a bionic baroreflex system prevent sudden hypotension in patients undergoing surgery?
Does a bionic baroreflex system prevent sudden hypotension in patients undergoing surgery?
Absolute Event Rate: 1% vs 25%
An artificial bionic baroreflex system can effectively attenuate sudden hypotension by automatically regulating sympathetic vasomotor tone.
BBS feasible in surgical hypotension; leaves open efficacy for central baroreflex failure.
BACKGROUND: We proposed a novel therapeutic strategy against central baroreflex failure: implementation of an artificial baroreflex system to automatically regulate sympathetic vasomotor tone, ie, a bionic baroreflex system (BBS), and we tested its efficacy in a model of sudden hypotension during surgery. METHODS AND RESULTS: The BBS consisted of a computer-controlled negative-feedback circuit that sensed arterial pressure (AP) and automatically computed the frequency (STM) of a pulse train required to stimulate sympathetic nerves via an epidural catheter placed at the level of the lower thoracic spinal cord. An operation rule was subsequently designed for the BBS using a feedback correction with proportional and integral gain factors. The transfer function from STM to AP was identified by a white noise system identification method in 12 sevoflurane-anesthetized patients undergoing orthopedic surgery involving the cervical vertebrae, and the feedback correction factors were determined with a numerical simulation to enable the BBS to quickly and stably attenuate an external disturbance on AP. The performance of the designed BBS was then examined in a model of orthostatic hypotension during knee joint surgery (n=21). Without the implementation of the BBS, a sudden deflation of a thigh tourniquet resulted in a 17+/-3 mm Hg decrease in AP within 10 seconds and a 25+/-2 mm Hg decrease in AP within 50 seconds. By contrast, during real-time execution of the BBS, the decrease in AP was 9+/-2 mm Hg at 10 seconds and 1+/-2 mm Hg at 50 seconds after the deflation. CONCLUSIONS: These results suggest the feasibility of a BBS approach for central baroreflex failure.
No takes yet. Share an insight, caveat, or question.
Yamasaki et al. (2006) studied Sudden hypotension during surgery (n=33). Bionic baroreflex system (BBS) vs. Without the implementation of the BBS was evaluated on Decrease in arterial pressure at 50 seconds after sudden deflation of a thigh tourniquet. A bionic baroreflex system attenuated the decrease in arterial pressure following thigh tourniquet deflation to 1+/-2 mm Hg at 50 seconds, compared to 25+/-2 mm Hg without the system.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: