Key result
The nonlinear correlation index D showed a stronger monotonic relationship with the estimated depth of Sevoflurane anesthesia compared to the bispectral index.
Why the study?
Does the nonlinear correlation index D better indicate depth of anesthesia compared to established spectral measures in patients anesthetized with sevoflurane?
Observational (n=17)
Does the nonlinear correlation index D better indicate depth of anesthesia compared to established spectral measures in patients anesthetized with sevoflurane?
A phase space-based nonlinear correlation index (D) of EEG signals may provide a more reliable indicator of anesthesia depth than traditional spectral measures.
Answers are grounded in this paper and cite their sources.
D may better track sevoflurane depth than BIS; this Level 5 finding leaves open prospective validation before any practice change.
We investigate several quantifiers of the electroencephalogram (EEG) signal with respect to their ability to indicate depth of anesthesia. For 17 patients anesthetized with sevoflurane, three established measures (two spectral and one based on the bispectrum), as well as a phase space based nonlinear correlation index were computed from consecutive EEG epochs. In the absence of an independent way to determine anesthesia depth, the standard was derived from measured blood plasma concentrations of the anesthetic via a pharmacokinetic/pharmacodynamic model for the estimated effective brain concentration of sevoflurane. In most patients, the highest correlation is observed for the nonlinear correlation index D*. In contrast to spectral measures, D* is found to decrease monotonically with increasing (estimated) depth of anesthesia, even when a "burst-suppression" pattern occurs in the EEG. The findings show the potential for applications of concepts derived from the theory of nonlinear dynamics, even if little can be assumed about the process under investigation.
No takes yet. Share an insight, caveat, or question.
Widman et al. (2000) conducted an observational in Patients undergoing elective surgery requiring anesthesia (n=17). Nonlinear correlation index D (EEG measure) vs. Bispectral index (bis) and spectral measures (fmedian, fse95) was evaluated on Spearman's rank correlation coefficient (ρ) between estimated effective brain concentration of Sevoflurane and EEG measure (p=<0.05). The nonlinear correlation index D showed a stronger monotonic relationship with the estimated depth of Sevoflurane anesthesia compared to the bispectral index.
Synapse has enriched 10 related papers. Consider them for comparative context: