Key result
Premature ovarian insufficiency was associated with an impaired myocardial performance index compared to healthy controls (0.9 vs. 0.5, p<0.001), while pulse wave velocity did not differ.
Why the study?
Does premature ovarian insufficiency affect pulse wave velocity and myocardial performance index compared to healthy controls?
Case-Control (n=100)
Does premature ovarian insufficiency affect pulse wave velocity and myocardial performance index compared to healthy controls?
Absolute Event Rate: 0.9% vs 0.5%
p-value: p=<0.001
Premature ovarian insufficiency is associated with impaired global left ventricular function as measured by myocardial performance index, but not with increased arterial stiffness as measured by pulse wave velocity.
OBJECTIVE: Epidemiological studies suggest that women with loss of ovarian function at early ages may be especially burdened by cardiovascular disease (CVD). In this study, we aimed to evaluate pulse wave velocity (PWV) and myocardial performance index (MPI) in patients with premature ovarian insufficiency (POI). DESIGN: We enrolled 51 female patients (mean age 38.9 ± 6.7 years) with POI and 49 healthy subjects (mean age 36.8 ± 5.2 years). All participants underwent a detailed echocardiographic examination and PWV measurement, which is basically the velocity of pulse wave travelling from carotid to femoral artery. RESULTS: Both groups were similar with regard to age, body mass index (BMI) and left ventricular ejection fraction. When diastolic functions were assessed, patients with POI had higher mean E/E'ratio (9.3 ± 1.9 vs. 7.6 ± 1.6, p < 0.001). POI patients have impaired MPI (0.9 ± 0.5 vs. 0.5 ± 0.2, p < 0.001) comparing to healthy controls but PWV measurements did not differ between two groups (5.7 ± 0.8 vs. 5.6 ± 0.6 m/s, p = 0.48). CONCLUSIONS: This study showed POI patients might have impaired global left ventricular functions comparing to age matched healthy controls and this might reflect the effects of premature lack of estrogen (E) on women's cardiovascular (CV) system.
No takes yet. Share an insight, caveat, or question.
Aksoy et al. (2017) conducted a case-control in Premature ovarian insufficiency (n=100). Premature ovarian insufficiency vs. Healthy controls was evaluated on Myocardial performance index (MPI) (p=<0.001). Premature ovarian insufficiency was associated with an impaired myocardial performance index compared to healthy controls (0.9 vs. 0.5, p<0.001), while pulse wave velocity did not differ.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: