Key result
Peripheral intravenous rt-PA administration resulted in angiographic evidence of clot lysis in 94% of patients with acute pulmonary embolism by 6 hours.
Why the study?
Does peripheral intravenous rt-PA improve angiographic clot lysis and hemodynamics in patients with acute pulmonary embolism?
Does peripheral intravenous rt-PA improve angiographic clot lysis and hemodynamics in patients with acute pulmonary embolism?
Peripheral intravenous rt-PA is associated with rapid clot lysis, improved pulmonary perfusion, and improved right ventricular function in patients with acute pulmonary embolism.
Hypothesis-generating for peripheral IV rt-PA in acute PE; leaves open need for RCTs on safety and outcomes.
We assessed the efficacy and safety of peripheral intravenous recombinant human tissue-type plasminogen activator (rt-PA) in 47 patients with angiographically documented pulmonary embolism (PE). We administered 50 mg/2 h and, if necessary, an additional 40 mg/4 h. By 6 hours, 94% of the patients had angiographic evidence of clot lysis that was slight in 5, moderate in 12, and marked in 27 patients. Among the 34 patients with pulmonary hypertension prior to treatment, average pulmonary artery pressure decreased from 43/17 (27) to 31/13 (19) mm Hg (P less than 0.0001). The average lung scan perfusion defect decreased from 37% before therapy to 16% (P less than 0.01) after therapy among the 19 patients who had pre- and post-treatment lung scans. Of 7 patients with pre- and post-treatment imaging and Doppler echocardiograms, hypokinetic right ventricular wall movement (mild in 1, moderate in 2, and severe in 4) normalized in 5 and improved to mild hypokinesis in 2. Right ventricular diameter decreased from 3.9 +/- 1.0 to 2.0 +/- 0.5 cm (P less than 0.005). Fibrinogen decreased 33% from baseline at 2 h and 42% from baseline at 6 h. However, patients with the greatest degree of angiographic clot lysis at 2 h had a preponderance of fibrinogenolysis over fibrinolysis, demonstrated by a lower ratio of cross-linked fibrin degradation products to fibrin(ogen) degradation products (0.14 +/- 0.09 vs. 0.54 +/- 0.82) (P less than 0.04). Among selected patients, peripheral intravenous rt-PA is associated with rapid lysis of PE, improved pulmonary perfusion, and improved right ventricular function.
No takes yet. Share an insight, caveat, or question.
Goldhaber et al. (1988) studied acute pulmonary embolism (n=47). recombinant human tissue-type plasminogen activator (rt-PA) was evaluated on angiographic evidence of clot lysis at 6 hours. Peripheral intravenous rt-PA administration resulted in angiographic evidence of clot lysis in 94% of patients with acute pulmonary embolism by 6 hours.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: