Key result
In a computational model, severe mitral prosthesis-patient mismatch induced high pulmonary arterial pressure, suggesting a cutoff iEOA of approximately 1.16 cm2/m2 to define PPM at rest.
Why the study?
What are the appropriate indexed effective orifice area (iEOA) cutoff values for defining mitral prosthesis-patient mismatch (PPM) and its impact on pulmonary arterial pressure?
What are the appropriate indexed effective orifice area (iEOA) cutoff values for defining mitral prosthesis-patient mismatch (PPM) and its impact on pulmonary arterial pressure?
Computational modeling demonstrates that small iEOA values (severe PPM) induce high pulmonary arterial pressure, suggesting a cutoff of 1.16 cm2/m2 for PPM at rest.
Suggests reevaluating mitral PPM iEOA thresholds to limit pulmonary hypertension; leaves open prospective clinical validation.
Recent clinical studies reported that prosthesis-patient mismatch (PPM) becomes clinically relevant when the effective orifice area (EOA) indexed by the body surface area (iEOA) is <1.2-1.25 cm(2)/m(2). To examine the effect of PPM on transmitral pressure gradient and left atrial (LA) and pulmonary arterial (PA) pressures and to validate the PPM cutoff values, we used a lumped model to compute instantaneous pressures, volumes, and flows into the left-sided heart and the pulmonary and systemic circulations. We simulated hemodynamic conditions at low cardiac output, at rest, and at three levels of exercise. The iEOA was varied from 0.44 to 1.67 cm(2)/m(2). We normalized the mean pressure gradient by the square of mean mitral flow indexed by the body surface area to determine at which cutoff values of iEOA the impact of PPM becomes hemodynamically significant. In vivo data were used to validate the numerical study, which shows that small values of iEOA (severe PPM) induce high PA pressure (residual PA hypertension) and contribute to its nonnormalization following a valve replacement, providing a justification for implementation of operative strategies to prevent PPM. Furthermore, we emphasize the major impact of pulmonary resistance and compliance on PA pressure. The model suggests also that the cutoff iEOA that should be used to define PPM at rest in the mitral position is approximately 1.16 cm(2)/m(2). At higher levels of exercise, the threshold for iEOA is rather close to 1.5 cm(2)/m(2). Severe PPM should be considered when iEOA is <0.94 cm(2)/m(2) at rest.
No takes yet. Share an insight, caveat, or question.
Tanné et al. (2008) studied Mitral prosthesis-patient mismatch and pulmonary hypertension. Mitral prosthesis-patient mismatch (PPM) was evaluated on Transmitral pressure gradient and left atrial and pulmonary arterial pressures. In a computational model, severe mitral prosthesis-patient mismatch induced high pulmonary arterial pressure, suggesting a cutoff iEOA of approximately 1.16 cm2/m2 to define PPM at rest.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: