Key result
21-day intermittent screening with a hand-held ECG recorder detected more paroxysmal atrial fibrillation after ischemic stroke or TIA than 48-hour Holter monitoring (11.4% vs 2.8%; P=0.001).
Why the study?
Does 21-day intermittent screening with a hand-held ECG recorder improve detection of paroxysmal atrial fibrillation compared to 48-hour Holter monitoring in patients after ischemic stroke and TIA?
Observational (n=360)
No
Does 21-day intermittent screening with a hand-held ECG recorder improve detection of paroxysmal atrial fibrillation compared to 48-hour Holter monitoring in patients after ischemic stroke and TIA?
Absolute Event Rate: 11.4% vs 2.8%
p-value: p=0.001
Prolonged intermittent screening with a hand-held ECG recorder for 21 days significantly increases the detection of paroxysmal atrial fibrillation after ischemic stroke or TIA compared to 48-hour Holter monitoring.
May support prolonged intermittent ECG screening post-stroke/TIA; hypothesis-generating and requires prospective confirmation before practice change.
Aims . Screening of paroxysmal atrial fibrillation (PAF) after ischemic stroke and TIA is important. The ideal method is not known and studies of intermittent screening methods in particular are lacking. In this retrospective study we compared a shorter continuous screening method with an intermittent screening method. Methods . Since early 2011 our stroke unit has used two different methods of screening: either a 48-hour continuous screening with Holter monitor or a 21-day twice daily intermittent screening with a hand-held ECG recorder. Through the Swedish National Stroke Registry and medical records reviewing all screening episodes between 2011-02-01 and 2013-01-31 were collected and analysed. Results . Of 386 screenings, 26 screenings were excluded leaving 360 screenings for the final analysis of which 114 screenings were made with hand-held ECG recorder and 246 with Holter monitoring. No significant difference between the groups concerning basic characteristics was observed. In the hand-held ECG recorder group a total of 13 PAF screenings (11.4%) were detected compared with 7 (2,8%) in the Holter group (P=0.001). Conclusions . A prolonged intermittent screening is a better method than a shorter continuous screening in terms of detecting PAF after ischemic stroke and TIA.
No takes yet. Share an insight, caveat, or question.
Orrsjö et al. (2014) conducted an observational in Ischemic stroke and TIA (n=360). 21-day twice daily intermittent screening with a hand-held ECG recorder vs. 48-hour continuous screening with Holter monitor was evaluated on Detection of paroxysmal atrial fibrillation (PAF) (p=0.001). 21-day intermittent screening with a hand-held ECG recorder detected more paroxysmal atrial fibrillation after ischemic stroke or TIA than 48-hour Holter monitoring (11.4% vs 2.8%; P=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: