Key result
Pulmonary vein isolation using open irrigated tip catheters was superior to conventional 4 mm tip catheters for maintaining sinus rhythm at 3.5 months (73% vs 45%, p=0.03).
Why the study?
Does pulmonary vein isolation using an open irrigated tip catheter improve maintenance of sinus rhythm compared to a standard non-irrigated catheter in patients with atrial fibrillation?
Cohort (n=79)
Does pulmonary vein isolation using an open irrigated tip catheter improve maintenance of sinus rhythm compared to a standard non-irrigated catheter in patients with atrial fibrillation?
Open irrigated tip catheters for pulmonary vein isolation significantly improve the maintenance of sinus rhythm and reduce recurrent atrial fibrillation compared to standard non-irrigated catheters.
Answers are grounded in this paper and cite their sources.
Irrigated catheters for PVI may offer procedural advantages; leaves open relative efficacy and safety versus non-irrigated in randomized data.
AIMS: The relative efficacy and safety of open irrigated tip catheters compared with conventional non-irrigated catheters for pulmonary vein isolation (PVI) is unknown. METHODS: Forty-eight patients undergoing PVI using an open irrigated tip ablation catheter (Group 1) were compared with a group of 31 historical controls (Group 2). The control group underwent similar procedures using a standard, 4 mm tip, temperature controlled ablation catheter. Electrical mapping with a circular catheter was used to guide segmental radiofrequency ablation at the vein ostia. RESULTS: At follow-up (3.5+/-3.5 months) after a single procedure 35/48 (73%) patients in Group 1 and 14/31 (45%) in Group 2 were in sinus rhythm (p=0.03). Antiarrhythmic drug use was lower among those in Group 1 maintained in sinus rhythm (9/35 (26%) vs 8/14 (57%), p=0.002). Recurrent atrial fibrillation was more common in Group 2 (28/31 (90%) vs 28/48 (58%) p=0.004). Serious complications were uncommon in both groups. CONCLUSIONS: Compared with an historical control group, pulmonary vein isolation using open irrigated tip catheters was superior to ablation with conventional 4 mm tip catheters. Patients undergoing ablation with an irrigated tip catheter were less likely to experience symptomatic recurrences of atrial fibrillation or require further therapy for post-procedural arrhythmias.
No takes yet. Share an insight, caveat, or question.
Sophie Thomas (2004) conducted a cohort in Atrial fibrillation (n=79). Open irrigated tip ablation catheter vs. Standard 4 mm tip temperature controlled ablation catheter (historical controls) was evaluated on Maintenance of sinus rhythm after a single procedure (p=0.03). Pulmonary vein isolation using open irrigated tip catheters was superior to conventional 4 mm tip catheters for maintaining sinus rhythm at 3.5 months (73% vs 45%, p=0.03).
Synapse has enriched 10 related papers. Consider them for comparative context: