Answers are grounded in this paper and cite their sources.
Dynamic light scattering (DLS) is commonly employed to estimate the hydrodynamic radius of particles ( R H ) and less commonly to assess colloidal stability. Here we suggest DLS can also be used to study the interface between the particle and the surrounding water. DLS R H measurement have two sources of systematic error. Attraction and repulsion between particles alter the apparent R H in concentration dependent manner referred to as the interaction parameter ( k D ). The second systematic error, which is not concentration dependent, is observed as a change in the calculated hydrodynamic radius at infinite dilution ( R H,0 ). If the actual R H,0 is unchanged, the variation can be attributed to a change in apparent viscosity ( η app ) and that η app is the viscosity at the slipping plane. Pegylated lipid nanoparticles (LNPs) were measured at various temperatures using DLS. The calculated R H,0 of the LNPs decreased markedly with rising temperature. The authors suggest that the radius is unlikely to change, but the η app decreased with an increase in temperature. Salts from the Hofmeister series caused a minimal change in the R H,0 , η app or k D values. This suggests that charge screening is not a key determinant of LNP colloidal stability. The addition of isopropanol increased the η app values. This suggests that both isopropanol and temperature affect the apparent viscosity at the slipping plane between the pegylated LNP and water
No takes yet. Share an insight, caveat, or question.
Francis et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: