Answers are grounded in this paper and cite their sources.
All known requisites for precision and accuracy within 1 X 10-a in refractive index were employed in these determinations made by the minimum-deviation method using specially designed hollow prisms and platinum resistance thermometers. The data were adjusted by least squares and are represented by a general formula having 13 constants, the average of the 133 residuals being 1.2 X 10-a. A general double-entry table of refractive indices (6,776 listings) with temperature and wave length as arguments has been computed to yield sixthdecimal data by linear interpolation. The maximum refractivity of water is found to be near 0 C, but the exact temperature thereof is a function of wave length, with a total variation of approximately 0.5 C for th e visible spectral range. Other more specific tables of indices are given, and evidences of slight systematic errors are discussed . The attained precision is approximately as expected, but there is marked disagreement with some of Flatow's indices, which have been widely used and are the basis for the data on water as given in the International Critical Tables. The authors' opinions concerning the accuracy of their results are qualitatively confirmed by the medial relation of their data to all of those previously published, and quantitatively, within the t emperature r ange o to 16 C, there is remarkably elose agreement with the interferometrically determined indices of water, as reported by Mlle. O. Jasse.
No takes yet. Share an insight, caveat, or question.
Tilton et al. (1938) studied this question.