Key result
Intravenous ultrasound contrast agents were safe in pediatric oncology patients, causing no detrimental hemodynamic changes and mild transient side effects in only 2.2% of examinations.
Why the study?
Are intravenous ultrasound contrast agents safe and well-tolerated in pediatric oncology patients?
Observational (n=34)
No
Are intravenous ultrasound contrast agents safe and well-tolerated in pediatric oncology patients?
Intravenous ultrasound contrast agents appear safe and well-tolerated in pediatric oncology patients, with no significant hemodynamic changes and rare, mild side effects.
May support contrast use in select pediatric oncology cases; leaves open need for prospective confirmation before wider adoption.
OBJECTIVE: Little information is available regarding the safety of ultrasound contrast agents in children. The purpose of this article was to assess the safety profile of the i.v. administration of ultrasound contrast agents in the pediatric oncology population. MATERIALS AND METHODS: Patients with pediatric solid malignancies who were enrolled on institutional clinical trials conducted between June 2003 and January 2013 and who met our institutional screening criteria for contrast-enhanced ultrasound (CEUS) were eligible. After providing informed consent or assent for CEUS, subjects received i.v. bolus injections of one of two contrast agents for imaging of the primary tumor or a metastatic target lesion. Hemodynamic parameters, including heart rate, cardiac rhythm, and oxygen saturation, were monitored immediately before and for 30 minutes after the administration of the contrast agent. Interviews with the subject or a guardian were conducted by the principal investigator or a radiologist coinvestigator before and after the examination to assess for any adverse effects. RESULTS: Thirty-four subjects (21 male and 13 female) ranging in age from 8 months to 20.7 years (median, 8.7 years) underwent 134 CEUS. No detrimental change in hemodynamic status occurred in any subject. Three subjects (3/134, 2.2%) reported mild transient side effects on one occasion each, two (2/134, 1.5%) had taste alteration, and one (1/134, 0.8%) reported mild transient tinnitus and lightheadedness. These reactions did not recur in these subjects on subsequent CEUS examinations. CONCLUSION: The i.v. administration of ultrasound contrast agents is safe and well tolerated in the pediatric oncology population. Further studies in children are needed to confirm our findings.
No takes yet. Share an insight, caveat, or question.
Coleman et al. (2014) conducted an observational in Pediatric solid malignancies (n=34). Intravenous ultrasound contrast agents was evaluated on Adverse effects and hemodynamic changes. Intravenous ultrasound contrast agents were safe in pediatric oncology patients, causing no detrimental hemodynamic changes and mild transient side effects in only 2.2% of examinations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: