Key result
Inappropriate use of adenosine by paramedics for presumed PSVT occurred in 20% of cases, and was associated with initial heart rate <160 beats/min and no history of PSVT.
Why the study?
What is the rate of rhythm misidentification by paramedics treating presumed PSVT with adenosine, and what factors are associated with inappropriate use?
Observational (n=224)
What is the rate of rhythm misidentification by paramedics treating presumed PSVT with adenosine, and what factors are associated with inappropriate use?
Paramedics misidentified rhythms in 20% of presumed PSVT cases treated with adenosine, with errors more common when the initial heart rate was <160 bpm or patients lacked a history of palpitations.
Answers are grounded in this paper and cite their sources.
Paramedic adenosine use for presumed PSVT showed notable misidentification; leaves open questions on EMS training efficacy pending prospective studies.
OBJECTIVES: To examine trends in paramedic rhythm misidentification rates in the use of adenosine for presumed paroxysmal supraventricular tachycardia (PSVT) over a ten-year period, and to determine variables associated with rhythm misidentification. METHODS: The authors conducted a retrospective analysis of all cases in which paramedics treated presumed PSVT with adenosine from 1993 to 2002. Rhythm strips were categorized as narrow or wide-complex and regular or irregular. Appropriate use of adenosine was defined as narrow-complex regular tachycardia with no visible P waves and rate greater than 140 beats/min. RESULTS: The authors studied 224 patients with a mean age of 60 years (range, 15-94 years); 157 (70%) were female and predominantly white. The majority (54%) of patients had initial heart rates of 161-200 beats/min. Forty-nine percent of the patients had a previous history of PSVT. Inappropriate use of adenosine occurred in 45 (20%) cases. Misidentification rates per year ranged from 9% to 31% with the lowest rate occurring after a targeted education program on tachydysrhythmias. An initial heart rate of <160 beats/min (chi(2)=14.81, p<0.001) and absence of a medical history of either fast heart rate or palpitations (chi(2)=11.35, p=0.001) were associated with inappropriate use of adenosine. CONCLUSION: Paramedics in this emergency medical services system are more likely to use adenosine appropriately for patients with initial heart rates of >160 beats/min and a history of rapid heart rate or palpitations. Further studies are required to identify factors associated with rhythm interpretation errors in the prehospital setting as well as to evaluate error reduction strategies.
No takes yet. Share an insight, caveat, or question.
Phillip J Goebel (2004) conducted an observational in Presumed paroxysmal supraventricular tachycardia (PSVT) (n=224). Paramedic treatment with adenosine for presumed PSVT was evaluated on Inappropriate use of adenosine (rhythm misidentification). Inappropriate use of adenosine by paramedics for presumed PSVT occurred in 20% of cases, and was associated with initial heart rate <160 beats/min and no history of PSVT.
Synapse has enriched 10 related papers. Consider them for comparative context: