Key result
A sensitive troponin assay measured at arrival and 2 hours later achieved 100% sensitivity and 87% specificity for detecting myocardial infarction using a simple algorithm.
Why the study?
Does a sensitive troponin assay improve the rapid detection of myocardial infarction in emergency department patients suspected of non-ST-elevation acute coronary syndrome?
Observational (n=157)
Does a sensitive troponin assay improve the rapid detection of myocardial infarction in emergency department patients suspected of non-ST-elevation acute coronary syndrome?
A sensitive troponin assay enables accurate diagnosis of myocardial infarction within 2 hours of emergency department arrival, rendering creatine kinase-MB and myoglobin measurements unnecessary.
May support 2-hour troponin assessment for MI in ED; leaves open prospective validation before practice change.
Rapid identification and treatment of patients with a myocardial infarction (MI) is mandatory. We studied the diagnostic capacities of a sensitive troponin assay for detection of MI in emergency department patients within 2 hours after arrival. The study included 157 patients suspected of having non-ST-elevation acute coronary syndrome. Blood was drawn on arrival (T0) and 2 (T2), 6, and 12 hours later. At T2, a troponin concentration above the MI cutoff is 87% sensitive and 100% specific for MI detection (positive predictive value [PPV], 100%; negative predictive value [NPV], 96%). If a difference of more than 30% between the troponin measurements at T0 and T2 in the absence of an absolute troponin increase above the 99th percentile of a reference population is also considered indicative of MI, the sensitivity increases to 100% and specificity decreases to 87% (PPV, 70%; NPV, 100%). Sensitivity and specificity of creatine kinase-MB and myoglobin are lower than those of troponin. By using a sensitive troponin assay and simple algorithms, the diagnosis of MI can be determined within 2 hours after arrival at the emergency department. Measurement of myoglobin and creatine kinase-MB has no added value.
No takes yet. Share an insight, caveat, or question.
Scharnhorst et al. (2011) conducted an observational in Suspected non-ST-elevation acute coronary syndrome (n=157). Sensitive troponin assay vs. Creatine kinase-MB and myoglobin was evaluated on Detection of myocardial infarction. A sensitive troponin assay measured at arrival and 2 hours later achieved 100% sensitivity and 87% specificity for detecting myocardial infarction using a simple algorithm.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: