Key result
The model clamp technique demonstrated that critical coupling conductance for frequency entrainment between real and simulated rabbit sinoatrial node cells ranged from 50 to 300 pS in 11 cell pairs.
A novel 'model clamp' technique allows real-time coupling of isolated rabbit sinoatrial node cells to mathematical models to study electrical synchronization and gap junctional interactions.
Enables real-time study of gap junctional coupling in cardiac cells; leaves open translation to disease models.
A method for coupling an isolated cardiac cell to a simulated cardiac cell, i.e., the real-time solution of a mathematical model of such cell, has been developed. With this "model clamp" technique, the real cell and the model cell are coupled by any desired value of intercellular coupling conductance, producing the effect of mutual interaction by electrical coupling through gap junctional channels. We implemented the model clamp technique with our previously published model of an isolated rabbit sinoatrial node cell. We used this model clamp system to study synchronization of sinoatrial node cells with regard to the critical value of intercellular coupling conductance required for frequency entrainment and the common interbeat interval during frequency entrainment. This common interbeat interval lay between the intrinsic intervals of the real cell and the model cell, but was closer to that of the intrinsically faster beating cell. Critical coupling conductance increased with increasing difference in intrinsic interbeat interval of the real cell and the model cell and ranged between 50 and 300 pS in 11 hybrid cell pairs.
No takes yet. Share an insight, caveat, or question.
Wilders et al. (1996) studied Synchronization of sinoatrial node cells (n=11). Model clamp technique was evaluated on Critical value of intercellular coupling conductance required for frequency entrainment and common interbeat interval. The model clamp technique demonstrated that critical coupling conductance for frequency entrainment between real and simulated rabbit sinoatrial node cells ranged from 50 to 300 pS in 11 cell pairs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: