Key result
Vasodilator stress cardiac MRI and 320-detector row coronary CTA were highly concordant and both demonstrated high diagnostic accuracy for detecting obstructive CAD.
Why the study?
What is the concordance and diagnostic accuracy of vasodilator stress CMR and 320-detector row coronary CTA for detecting obstructive CAD in patients with suspected CAD?
Observational (n=151)
Blinded readers
No
What is the concordance and diagnostic accuracy of vasodilator stress CMR and 320-detector row coronary CTA for detecting obstructive CAD in patients with suspected CAD?
Answers are grounded in this paper and cite their sources.
Moderate concordance between stress CMR and CTA; leaves open optimal strategy and requires prospective outcome trials.
Vasodilator stress cardiac magnetic resonance (CMR) detects ischemia whereas coronary CT angiography (CTA) detects atherosclerosis. The purpose of this study was to determine concordance and accuracy of vasodilator stress CMR and coronary CTA in the same subjects. We studied 151 consecutive subjects referred to detect or exclude suspected obstructive coronary artery disease (CAD) in patients without known disease or recurrent stenosis or ischemia in patients with previously treated CAD. Vasodilator stress CMR was performed on a 1.5 T scanner. CTA was performed on a 320-detector row system. Subjects were followed for cardiovascular events and downstream diagnostic testing. Subjects averaged 56 ± 12 years (60% male), and 62 % had intermediate pre-test probability for obstructive CAD. Follow-up averaged 450 ± 115 days and was 100% complete. CMR and CTA agreed in 92% of cases (κ 0.81, p < 0.001). The event-free survival was 97 % for non-ischemic and 39% for ischemic CMR (p < 0.0001). The event-free survival was 99% for non-obstructive and 36% for obstructive CTA (p < 0.0001). Using a reference standard including quantitative invasive angiography or major cardiovascular events, CMR and CTA had respective sensitivities of 93 and 98 %; specificities of 96 and 96%; positive predictive values of 91 and 91%; negative predictive values of 97 and 99%; and accuracies of 95 and 97%. Non-ischemic vasodilator stress CMR or non-obstructive coronary CTA were highly concordant and each confer an excellent prognosis. CMR and CTA are both accurate for assessment of obstructive CAD in a predominantly intermediate risk population.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2013) conducted an observational in Suspected obstructive coronary artery disease (n=151). Vasodilator stress cardiac MRI and 320-detector row coronary CTA vs. Invasive angiography or clinical outcomes was evaluated on Concordance between CMR and CTA (κ 0.81, p=<0.001). Vasodilator stress cardiac MRI and 320-detector row coronary CTA were highly concordant and both demonstrated high diagnostic accuracy for detecting obstructive CAD.
Synapse has enriched 10 related papers. Consider them for comparative context: