Key result
Pleuro-pericardial window successfully resolves recurrent pericardial effusion after epicardial pacemaker lead placement.
Why the study?
Pericardial effusion and tamponade are rare but serious complications of epicardial pacemaker placement.
Case Report (n=1)
No
Pleuro-pericardial window surgery may serve as an effective, less invasive alternative to total pericardiectomy for managing recurrent pericardial effusions after epicardial pacing system implantation.
Answers are grounded in this paper and cite their sources.
May avoid pericardiectomy in select post-epicardial pacing effusions; leaves open need for prospective confirmation.
Background: Epicardial pacemaker placement is often necessary in pacemaker-dependent patients with ongoing device pocket infection or lack of venous access. Pericardial effusion and tamponade are rare but serious complications of this procedure. Case summary: A 38-year-old woman presented with nausea, diaphoresis, and hypotension 7 days after epicardial lead placement. Echocardiography revealed a large pericardial effusion with signs of tamponade. Despite initial improvement after pericardiocentesis, she continued to develop symptomatic pericardial effusions. The patient ultimately underwent pleuro-pericardial window surgery, which resulted in sustained resolution of effusion recurrence. Discussion: Cases of recurrent pericardial effusion and tamponade following epicardial lead placement have been reported in the literature, although they are rare. While extensive partial pericardiectomy or total pericardiectomy was required to achieve adequate control of fluid accumulation in prior case reports, our patient was successfully managed with a pleuro-pericardial window.
No takes yet. Share an insight, caveat, or question.
Nguyen et al. (2022) conducted a case report in Recurrent pericardial effusion and tamponade after epicardial pacemaker lead placement (n=1). Pleuro-pericardial window surgery was evaluated on Resolution of pericardial effusion. Recurrent pericardial effusion and cardiac tamponade following epicardial pacemaker lead placement was successfully managed with a pleuro-pericardial window without requiring total pericardiectomy.
Synapse has enriched 10 related papers. Consider them for comparative context: