Answers are grounded in this paper and cite their sources.
Objective To investigate the accuracy of 3D-printing non-coplanar template (3D-PNCT) assisted 125I seed implantation with CT guidance in the pelvic recurrent cervical between the pre-plan and post-plan dosimetric parameters. Methods Nine patients with pelvic recurrent cervical cancer received 125I seed implantation under CT guidance assisted with 3D-PNCT. A pre-plan based brachytherapy treatment planning system (B-TPS) assisted with 3D-PNCT for seed needle depth, direction and angle was designed. The dosimetry parameters including homogeneity index (HI), dose of 90% target volume (D90), mPD, volume percent of 100%, 150% and 200% prescribed dose V100, V150 and V200 and organ at risk between the pre-plan and post-plan were compared. Results Total seeds number was 675 (median 44, 25-114) according to pre-plan, and 669 (median 47, 25-113) seeds were implanted actually. 138 needles need implant according to preplan, and 132 needles was implanted actually. The median angle deviation was 1.99°±2.94°(0°-13°). There was no significant difference of HI, EI and CI between per-and post-plan. The differences of D90, MPD, V100, V150 and V200 between pre-and post-plan were not significant. Conclusions The confidence of pre-plan and post-plan for 3D-PNCT assisted 125I seed implantation in the pelvic recurrent cervical cancer could be accurately performed under CT guidance.
No takes yet. Share an insight, caveat, or question.
江萍 et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: