Key result
A 1 SD decrease in flow-mediated dilation was associated with a 132-ml decrement in post-bronchodilator FEV1 and a 2.6% increase in CT percentage of emphysema in former smokers.
Why the study?
Is impaired flow-mediated dilation associated with lower pulmonary function and emphysema in former smokers?
Cross-Sectional (n=107)
Single-blind
No
Is impaired flow-mediated dilation associated with lower pulmonary function and emphysema in former smokers?
Answers are grounded in this paper and cite their sources.
Impaired endothelial function, as measured by flow-mediated dilation, is independently associated with lower FEV1 and higher CT emphysema percentage in former smokers, suggesting a link between vascular health and early COPD.
Rationale Basic science research suggests a causal role for endothelial dysfunction in chronic obstructive pulmonary disease (COPD). Clinical studies examining endothelial function are lacking, particularly early in the disease. Flow-mediated dilation (FMD) is a physiologic measure of endothelial reactivity to endogenous nitric oxide. Objectives We hypothesized that lower FMD among former smokers would be associated with lower post-bronchodilator FEV1, higher percentage of emphysema using computed tomography (CT) and lower diffusing capacity. Methods We measured FMD, pulmonary function, and CT percentage of emphysema in a random sample of 107 cotinine-confirmed former smokers in the ongoing EMCAP study. FMD was defined as percentage change in the brachial artery diameter with reactive hyperemia. Generalized additive models were used to adjust for potential confounders and assess linearity. Measurements and Main Results Mean age of participants was 71 ± 5 years, 46% were female, and pack-years averaged 48 ± 26. Mean FMD was 3.8 ± 3.1%; mean post-bronchodilator FEV1, 2.3 ± 0.8 L; and mean CT percentage of emphysema, 26 ± 10%. A 1 SD decrease in FMD was associated with a 132-ml (95% confidence interval, 16–248 ml; P = 0.03) decrement in post-bronchodilator FEV1 and a 2.6% (95% confidence interval, 0.5–4.7%; P = 0.02) increase in CT percentage of emphysema in fully adjusted models. These associations were linear across the spectrum from normality to disease, independent of smoking history, and also significant among participants without COPD. Associations with diffusing capacity were consistent but nonsignificant (P = 0.09). The FMD–FEV1 association was entirely attributable to percentage of emphysema. Conclusions Impaired endothelial function, as measured by FMD, was associated with lower FEV1 and higher CT percentage of emphysema in former smokers early in COPD.
No takes yet. Share an insight, caveat, or question.
Barr et al. (2007) conducted a cross-sectional in Chronic Obstructive Pulmonary Disease (COPD) and Emphysema (n=107). Flow-mediated dilation (FMD) vs. Higher FMD (per 1 SD change) was evaluated on Post-bronchodilator FEV1 (MD 132 ml, 95% CI 16-248, p=0.03). A 1 SD decrease in flow-mediated dilation was associated with a 132-ml decrement in post-bronchodilator FEV1 and a 2.6% increase in CT percentage of emphysema in former smokers.