Key result
A mean aortic gradient <40 mmHg was not an independent risk factor for mortality after TAVR; ejection fraction ≤35% increased cardiovascular mortality only with enlarged LV dimensions (p=0.0438).
Why the study?
Severe symptomatic aortic stenosis patients presenting with low-flow low-gradient features have a reported less favorable prognosis even after surgical or transcatheter treatment.
Does a mean aortic gradient <40 mmHg compared to ≥40 mmHg independently affect cardiovascular and all-cause mortality in patients undergoing balloon-expandable TAVR?
Cohort (n=1,051)
No
Does a mean aortic gradient <40 mmHg compared to ≥40 mmHg independently affect cardiovascular and all-cause mortality in patients undergoing balloon-expandable TAVR?
In patients undergoing TAVR, a low mean aortic gradient (<40 mmHg) is not independently associated with mortality; rather, reduced ejection fraction (≤35%) drives mortality risk primarily when accompanied by left ventricular enlargement.
Aims In the clinical practice a noteworthy proportion of severe symptomatic aortic stenosis patients presents with low-flow low-gradients features, these having reported a less favorable prognosis even when surgically or transcatheter treated. Methods and Results We retrospectively analyzed the prospectively collected data on 1051 consecutive patients undergone balloon-expandable transcatheter aortic valve replacement at our Institution from January 2008 to January 2020. We divided the population according with a mean aortic gradient (MAG) < or ≥40 mmHg and we performed a propensity-matched analysis based on the Society of Thoracic Surgery Score and age, obtaining two homogeneous groups of 314 patients each (Groups A and B, respectively). We then analyzed the outcomes of the two groups by implementing adjusted Cox models adjusted for significant clinical differences between the two groups, such as sex, ejection fraction, comorbidities and other variables not included in the propensity-matched analysis. The only variable associated with both cardiovascular and all-cause events was an ejection fraction ≤35%. Finally, a sensitivity analysis found that an ejection fraction ≤35% was associated with an increase cardiovascular and all-cause mortality only in patients with an indexed end-diastolic volume >97 ml/m2 (p = .0438 and .3363, respectively). Conclusions In our series a MAG <40 mmHg was not found to be per se an independent risk factor for cardiac and all-cause mortality after transcatheter aortic valve replacement. The ejection fraction was found to be an independent risk factor only in the context of enlarged left ventricular dimensions.
No takes yet. Share an insight, caveat, or question.
Gennari et al. (2022) conducted a cohort in Severe symptomatic aortic stenosis (n=1,051). Mean aortic gradient <40 mmHg vs. Mean aortic gradient ≥40 mmHg was evaluated on Cardiovascular and all-cause mortality. A mean aortic gradient <40 mmHg was not an independent risk factor for mortality after TAVR; ejection fraction ≤35% increased cardiovascular mortality only with enlarged LV dimensions (p=0.0438).