Key result
Discharge mean gradient <10 mm Hg after balloon-expandable ViV TAVR linked to ~15% higher 5-year mortality.
Why the study?
Lower discharge mean gradients after balloon-expandable TAVR are associated with lower EF and higher 5-year mortality, prompting investigation into whether echocardiographic mean gradient and patient-prosthesis mismatch correlate with clinical outcomes after valve-in-valve TAVR.
Does a discharge echocardiographic mean gradient <10 mm Hg increase 5-year mortality in patients undergoing aortic valve-in-valve replacement with balloon-expandable valves?
Does a discharge echocardiographic mean gradient <10 mm Hg increase 5-year mortality in patients undergoing aortic valve-in-valve replacement with balloon-expandable valves?
Following aortic valve-in-valve replacement with balloon-expandable valves, a low discharge mean gradient (<10 mm Hg) is associated with lower ejection fraction and increased 5-year mortality, whereas severe patient-prosthesis mismatch and high gradients (≥20 mm Hg) are not associated with worse 5-year outcomes.
BACKGROUND: Lower (<10 mm Hg) discharge echocardiographic mean gradients (MGs) following transcatheter aortic valve replacement with balloon-expandable valves are associated with lower ejection fraction and higher 5-year mortality compared with higher gradients. Using the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, we studied the relationship between echocardiographic MG and patient prosthesis mismatch (PPM) following transcatheter aortic valve-in-valve replacement and clinical outcomes. METHODS: Patients who underwent aortic valve-in-valve replacement with a balloon-expandable valve from July 2015 to December 2023 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were included. Adjusted Cox models with regression splines explored the relationship between MG and 5-year mortality. Kaplan-Meier estimates and adjusted hazard ratios compared the occurrence of 5-year mortality between gradient cutoffs and PPM presence. RESULTS: A total of 13 054 patients were included; spline curves demonstrated a nonlinear relationship between discharge MG and 5-year mortality. Kaplan-Meier curves suggested higher 5-year mortality with MG <10 mm Hg compared with MG ≥10 mm Hg (hazard ratio, 1.15 [95% CI, 1.02–1.29]; P =0.024). MG <10 mm Hg was associated with lower ejection fraction compared with higher MG (50.4±13.9 versus 53.2±12.8; P <0.0001). Severe PPM and MG ≥20 mm Hg were not associated with worse 5-year outcomes compared with none/moderate PPM or MG ≤20 mm Hg, respectively. CONCLUSIONS: Discharge MG <10 mm Hg are associated with lower ejection fraction and increased 5-year mortality following aortic valve-in-valve replacement compared with higher MG in a nonlinear fashion. Incorporating data on ejection fraction with PPM and MG is important before determining the need for valve optimization.
No takes yet. Share an insight, caveat, or question.
Abbas et al. (2026) studied this question. Discharge mean gradients <10 mm Hg after valve-in-valve TAVR with balloon-expandable valves were associated with 15% higher 5-year mortality (HR 1.15).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: