Key result
Equilibrium radionuclide angiocardiography using a slant-hole collimator showed excellent correlation with the first-pass technique for measuring right ventricular ejection fraction (r = 0.95).
Why the study?
Does equilibrium radionuclide angiocardiography with a slant-hole collimator accurately measure right ventricular ejection fraction compared to the first-pass technique?
Observational (n=31)
Does equilibrium radionuclide angiocardiography with a slant-hole collimator accurately measure right ventricular ejection fraction compared to the first-pass technique?
Effect estimate: r = 0.95
Equilibrium radionuclide angiocardiography with a slant-hole collimator provides an accurate and reproducible method for assessing right ventricular ejection fraction.
May support slant-hole equilibrium radionuclide angiocardiography for right ventricular ejection fraction; leaves open prospective outcome validation.
The authors developed and tested a simplified technique for measuring the right ventricular ejection fraction (RVEF). Following in vivo 99mTc red cell labeling, equilibrium (ECG-gated) radionuclide angiocardiography was performed in the modified left-anterior-oblique projection using a 30 degree slant-hold collimator. A single region-of-interest was defined from the ejection fraction image, and background was corrected. In 11 normal patients, the mean RVEF was 0.59 +/- 0.08 (SD). In 20 patients with suspected disease, who had RVEF measured by both equilibrium and first-pass techniques, the correlation between the two methods was excellent (r = 0.95; RVEF [first-pass] = 0.74 RVEF [equilibrium] + 0.03; Sy,x = 0.05). Interobserver correlation was also excellent (r = 0.98; Sy,x = 0.03), as was the correlation between RVEFs measured at least 60 minutes apart (r = 0.98; Sy,x = 0.03). This method was more accurate than alternative techniques, using either a background region-of-interest adjacent to the right ventricle or a fixed right ventricular region-of-interest which included the infundibulum. This simplified technique provides a reproducible method for the sequential quantitative assessment of right ventricular performance.
No takes yet. Share an insight, caveat, or question.
Holman et al. (1981) conducted an observational in Suspected heart disease (n=31). Equilibrium radionuclide angiocardiography using a 30 degree slant-hole collimator vs. First-pass technique was evaluated on Correlation of right ventricular ejection fraction between equilibrium and first-pass techniques (r = 0.95). Equilibrium radionuclide angiocardiography using a slant-hole collimator showed excellent correlation with the first-pass technique for measuring right ventricular ejection fraction (r = 0.95).