Key result
In patients with cardiomyopathy, maximum T wave alternans magnitude was significantly greater when measured from the entire body torso compared to standard clinical leads (p<0.005), resulting in an 11-21% false-negative rate for clinical leads.
Why the study?
Standard clinical ECG leads may not record T-wave alternans across the body torso, potentially causing false-negative tests if changing heart rate or ventricular activation alters its distribution.
Does body torso mapping improve the detection of T wave alternans compared to standard clinical leads during different pacing modes and heart rates in patients with cardiomyopathy?
Observational (n=28)
Yes
Does body torso mapping improve the detection of T wave alternans compared to standard clinical leads during different pacing modes and heart rates in patients with cardiomyopathy?
p-value: p=<0.005
Standard clinical ECG leads may miss clinically significant T wave alternans due to signal migration modulated by heart rate and ventricular activation sequence.
Standard leads risk false-negative TWA detection; leaves open need for optimized protocols in cardiomyopathy.
BACKGROUND: T wave alternans (TWA) is an electrocardiographic marker of heightened sudden death risk from ventricular tachyarrhythmias in patients with cardiomyopathy. TWA is evaluated from the 12-lead electrocardiogram, Frank lead, or Holter lead recordings, however these clinical lead configurations will not record TWA from adjacent regions of the body torso. OBJECTIVE: We tested the hypothesis that changing heart rate or ventricular activation may alter the body surface distribution of TWA such that the clinical ECG leads fail to detect TWA in some patients; thereby producing a false-negative test. METHODS: In 28 cardiomyopathy patients (left ventricular ejection fraction 28±6%), 114 unipolar electrograms were recorded across the body torso during incremental atrial pacing, followed by atrioventricular pacing at 100, 110 and 120bpm. TWA was measured from each unipolar electrogram using the spectral method. A clinically positive TWA test was defined as TWA magnitude (Valt) ≥1.9 uV with k ≥3 at ≤110bpm. RESULTS: Maximum Valt (TWAmax) was greater from the body torso than clinical leads during atrial (p<0.005) and atrioventricular pacing (p<0.005). TWAmax was most prevalent in the right lower chest with atrial pacing 100 bpm and shifted to the left lower chest at 120 bpm. TWAmax was most prevalent in left lower chest with atrioventricular pacing at 100 bpm and shifted to the left upper chest at 120 bpm. Using the body torso as a gold standard, the false-negative rate for clinically positive TWA with clinical leads was 21% during atrial and 11% during atrioventricular pacing. Due to TWA signal migration outside the clinical leads, clinically positive TWA became false-negative when pacing mode was switched (atrial→atrioventricular pacing) in 21% of patients. CONCLUSIONS: The body surface distribution of TWA is modulated by heart rate and the sequence of ventricular activation in patients with cardiomyopathy, which can give rise to modest false-negative TWA signal detection using standard clinical leads.
No takes yet. Share an insight, caveat, or question.
Ghoraani et al. (2019) conducted an observational in Cardiomyopathy (n=28). Body torso mapping during incremental atrial and atrioventricular pacing vs. Standard clinical leads was evaluated on Maximum T wave alternans magnitude (TWAmax) from body torso vs clinical leads (p=<0.005). In patients with cardiomyopathy, maximum T wave alternans magnitude was significantly greater when measured from the entire body torso compared to standard clinical leads (p<0.005), resulting in an 11-21% false-negative rate for clinical leads.