This paper introduces the application of the model order reduction (MOR) method using Laguerre polynomials in building envelope simulation. The dynamic heat transfer problems of a single-layer roof with the sinusoidal outdoor temperature as well as a multi-layer wall and a two-dimensional corner of wall under the realistic outside solar-air temperature were solved by the direct numerical solution method and Laguerre polynomial model order reduction (LP-MOR) method. The relative error, solution time, and heat flux of the LP-MOR and other MOR methods were compared. The maximum norm of relative errors between LP-MOR and the directly direct numerical solution (DNS) method based on finite volume method (FVM) can be controlled within 10−6. Moreover, compared with solving small-scale discrete systems, LP-MOR is more efficient in solving complex models with a large number of discrete nodes.
No takes yet. Share an insight, caveat, or question.
Kong et al. (2021) studied this question.