Key result
An infrared optical pacing system successfully controlled the beating rate of human cardiomyocyte monolayers, allowing accurate, contactless measurement of electrophysiological parameters without cellular damage.
A fully contactless infrared optical pacing and fluorescent imaging system can accurately and safely assess electrophysiological parameters and drug responses in human iPSC-derived cardiomyocyte monolayers, enabling high-throughput screening.
Answers are grounded in this paper and cite their sources.
Advances contactless optical pacing for cardiomyocyte studies; hypothesis-generating for broader applications pending in vivo validation.
Human cardiac myocytes derived from pluripotent stem cells (hCM) have invigorated interest in genetic disease mechanisms and cardiac safety testing; however, the technology to fully assess electrophysiological function in an assay that is amenable to high throughput screening has lagged. We describe a fully contactless system using optical pacing with an infrared (IR) laser and multi-site high fidelity fluorescence imaging to assess multiple electrophysiological parameters from hCM monolayers in a standard 96-well plate. Simultaneous multi-site action potentials (FluoVolt) or Ca2+ transients (Fluo4-AM) were measured, from which high resolution maps of conduction velocity and action potential duration (APD) were obtained in a single well. Energy thresholds for optical pacing were determined for cell plating density, laser spot size, pulse width, and wavelength and found to be within ranges reported previously for reliable pacing. Action potentials measured using FluoVolt and a microelectrode exhibited the same morphology and rate of depolarization. Importantly, we show that this can be achieved accurately with minimal damage to hCM due to optical pacing or fluorescence excitation. Finally, using this assay we demonstrate that hCM exhibit reproducible changes in repolarization and impulse conduction velocity for Flecainide and Quinidine, two well described reference compounds. In conclusion, we demonstrate a high fidelity electrophysiological screening assay that incorporates optical pacing with IR light to control beating rate of hCM monolayers.
No takes yet. Share an insight, caveat, or question.
McPheeters et al. (2017) studied Cardiac electrophysiology screening. Infrared optical pacing system with fluorescence imaging vs. Traditional microelectrode techniques was evaluated on Action potential duration and conduction velocity. An infrared optical pacing system successfully controlled the beating rate of human cardiomyocyte monolayers, allowing accurate, contactless measurement of electrophysiological parameters without cellular damage.