The neutron capture cross section of 243 Am were measured in the keV-energy region applying the implemented neutron filtering system of the Accurate Neutron-Nucleus Reaction Measurement Instrument beamline in the Materials and life science facility of the Japan Proton Accelerator Research Complex.A Si beam filter was used to obtain a quasi-monoenergetic neutron beam at averaged neutron energies of 51.5 and 127.7 keV.The neutron capture -rays were detected with a NaI(Tl) spectrometer.The pulse height weighting technique was employed to derive the neutron capture yield from pulse height spectra.The cross section was determined relative to the 197 Au capture cross section of JENDL-4.0.The results were obtained with higher accuracy than past available experimental data sets.