Key result
AV node ablation did not significantly decrease all-cause mortality compared to medical rate control (RR 0.70; 95% CI 0.23-2.10; P=0.5223) in patients with permanent AF and heart failure.
Why the study?
The benefit of AV node ablation over medical rate control for enhancing CRT response in permanent AF remains uncertain.
Does atrioventricular node ablation improve outcomes compared to medical rate control in adults with permanent or persistent atrial fibrillation and heart failure receiving or considered for CRT?
Meta-Analysis
Does atrioventricular node ablation improve outcomes compared to medical rate control in adults with permanent or persistent atrial fibrillation and heart failure receiving or considered for CRT?
Relative Risk: 0.7 (95% CI 0.23–2.1)
p-value: p=0.5223
In patients with permanent AF and heart failure receiving CRT, AV node ablation improves biventricular pacing and reduces inappropriate ICD therapies compared to medical rate control, but does not significantly reduce mortality.
The benefit of atrioventricular (AV) node ablation over medical rate control for enhancing cardiac resynchronization therapy (CRT) response in permanent atrial fibrillation remains uncertain. Four major databases were searched from inception to May 21, 2026. Eligible randomized controlled trials enrolled adults with permanent or persistent atrial fibrillation and heart failure receiving, or considered for, CRT. Outcomes included all-cause mortality, cardiovascular mortality, implantable cardioverter-defibrillator (ICD) therapies, and biventricular pacing percentage. Risk ratios (RRs) or mean differences with 95% confidence intervals (CIs) were pooled using inverse-variance methods. Five randomized controlled trials were included in our work, and 4 contributed to quantitative synthesis. No significant decrease in all-cause mortality was detected with AV node ablation (RR: 0.70, 95% CI, 0.23-2.10, P = 0.5223), the composite endpoint (RR: 0.79, 95% CI, 0.43-1.45, P = 0.4394), cardiovascular mortality (RR: 0.87, 95% CI, 0.42-1.79, P = 0.7022), or appropriate ICD therapy (RR: 0.93, 95% CI, 0.39-2.22, P = 0.8617). AV node ablation reduced inappropriate ICD therapy (RR: 0.09, 95% CI, 0.01-0.66; P = 0.0180) and increased biventricular pacing percentage (mean difference, 11.66%, 95% CI, 7.70-15.61; P < 0.0001). Sensitivity analyses were consistent. AV node ablation may improve CRT delivery and diminish inappropriate ICD therapy, but randomized evidence does not show consistent diminution in mortality or heart failure hospitalization.
No takes yet. Share an insight, caveat, or question.
Gadelmawla et al. (2026) conducted a meta-analysis in Permanent or persistent atrial fibrillation and heart failure. Atrioventricular (AV) node ablation vs. Medical rate control was evaluated on All-cause mortality (RR 0.70, 95% CI 0.23-2.10, p=0.5223). AV node ablation did not significantly decrease all-cause mortality compared to medical rate control (RR 0.70; 95% CI 0.23-2.10; P=0.5223) in patients with permanent AF and heart failure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: