Answers are grounded in this paper and cite their sources.
Cryo-electron microscopy (cryo-EM) has revolutionized structural biology by enabling visualization of biomolecules in near-native states without the need for crystallization [1,2]. In particular, it has transformed the study of large macromolecular assemblies and fibrillar aggregates, delivering near-atomic resolution structures. These advances have substantially improved our understanding of disease-associated proteins, protein–protein interactions, and molecular mechanisms, thereby accelerating structure-based drug discovery efforts [3,4]. Despite these achievements, high-resolution structure determination critically depends on robust and reproducible sample preparation. Conventional grid preparation relies on manual or semi-automated blotting to generate a thin aqueous film prior to plunge freezing. However, blotting-based approaches often lead to variable ice thickness, inconsistent particle distribution, preferred orientation, and potential protein denaturation at the air–water interface. These factors compromise reproducibility and can limit attainable resolution [5]. To address these limitations, we report the implementation and systematic characterization of an integrated microfluidic and robotic grid preparation workflow using the CryoWrite AG - cryoWriter® instrument, based on technology developed at the University of Basel [6,7]. The cryoWriter enables controlled deposition of nanoliter sample volumes onto EM grids without conventional blotting. We optimized operational parameters to enhance robustness and reproducibility. Using this platform, we generated high-quality grids that yielded single-particle reconstructions at sub-2 Å resolution while significantly reducing sample consumption. This approach broadens cryo-EM accessibility to biomolecules that are difficult to produce in large quantities [8]. Understanding protein–ligand–protein interactions on the grid with temporal resolution in the millisecond-to-second range remains challenging in the current state-of-art sample preparation methods. Capturing structural intermediates on these timescales is essential for elucidating the mechanisms of molecular machines and their regulation by small molecules. Such information is critical for structure-based drug design (SBDD), enabling identification of active sites, allosteric pockets, and transient conformational states. To investigate dynamic interaction states, we combine on-grid microfluidic mixing with rapid vitrification to trap reaction intermediates on the millisecond timescale. As a model system, we study the bacterial chaperonin GroEL–GroES, an ATP-driven protein-folding machine. Time and kinetically resolved structural snapshots reveal conformational transitions underlying its functional cycle. Together, these results establish an integrated microfluidic cryo-EM platform for studying dynamic macromolecular assemblies and provide a framework for mechanistic studies that support rational therapeutic development. Additionally, future studies will explore application of the cryoWriter system to cellular and tissue analysis. We aim to develop protocols for preparation and imaging of cells and fibrils using microfluidic capillaries. These advancements will further extend cryo-EM capabilities in structural and cellular biology, enabling new insights into complex biological systems. Atlas image showing sequential deposition of two samples on an EM grid. S1 indicates the first sample deposition, followed by deposition of the second sample (S2) at a 300 µm distance apart. Mixing of the two samples (protein–ligand in this case) is observed in the overlapping S1+S2 region, enabling data processing at different reaction time points (t) based on correlation with the cryoWriter instrument writing video. Scale bar: 200 µm.
No takes yet. Share an insight, caveat, or question.
Chinmaya et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: