Key result
A novel hybrid ECG denoising method based on VMD and EWT achieved an average output SNR of 24.03 and a 5% reduction in PRD compared to existing state-of-the-art methods.
Why the study?
Noises such as powerline interference and baseline wandering distort ECG signals during acquisition, which can lead to incorrect interpretation.
Does a hybrid ECG denoising method based on VMD and EWT improve signal-to-noise ratio and reduce percentage-root-mean-square difference compared to existing methods in ECG signals?
Does a hybrid ECG denoising method based on VMD and EWT improve signal-to-noise ratio and reduce percentage-root-mean-square difference compared to existing methods in ECG signals?
A novel hybrid ECG denoising method using VMD and EWT effectively removes powerline interference and baseline wandering, achieving higher SNR and lower PRD than existing methods.
May support ECG signal preprocessing; extends computational methods but leaves open clinical validation.
Electrocardiogram (ECG) is a critical biomedical signal and plays an imperative role in diagnosing cardiovascular disorders. During ECG data acquisition in clinical environment, noise is frequently present. Various noises such as powerline interference (PLI) and baseline wandering (BLW) distort the ECG signal which may lead to incorrect interpretation. Consequently, substantial emphasis has been dedicated to ECG denoising for reliable diagnosis and analysis. In this study, a novel hybrid ECG denoising method based on variational mode decomposition (VMD) and the empirical wavelet transform (EWT) is presented. For effective denoising using the VMD and EWT approach, the noisy ECG signal is decomposed within narrow-band variational mode functions (VMFs). The aim is to remove noise from these narrow-band VMFs. In current approach, the centre frequency of each VMF was computed and utilized to design an adaptive wavelet filter bank using EWT. This leads to effective removal of noise components from the signal. The proposed approach was applied to ECG signals obtained from the MIT-BIH Arrhythmia database. To evaluate the denoising performance, noise sources from the MIT-BIH Noise Stress Test Database (NSTDB) are used for simulation. The assessment of denoising performance in based on two key metrics: the percentage-root-mean-square difference (PRD) and the signal-to-noise ratio (SNR). The findings of the simulation experiment demonstrate that the suggested method has lower percentage root mean square difference and higher signal-to-noise ratio as compared to existing state of the art denoising methods. An average output SNR of 24.03 was achieved, along with a 5% reduction in PRD.
No takes yet. Share an insight, caveat, or question.
Mir et al. (2023) studied ECG denoising. Hybrid ECG denoising method based on variational mode decomposition (VMD) and empirical wavelet transform (EWT) vs. Existing state of the art denoising methods was evaluated on Percentage-root-mean-square difference (PRD) and signal-to-noise ratio (SNR). A novel hybrid ECG denoising method based on VMD and EWT achieved an average output SNR of 24.03 and a 5% reduction in PRD compared to existing state-of-the-art methods.