Key result
An inverted graft insertion technique for apicoaortic bypass permits simple and reliable suture placement without the need for any special device for the proximal anastomosis.
This novel inverted graft insertion technique simplifies the technically demanding proximal anastomosis in apicoaortic bypass surgery.
Answers are grounded in this paper and cite their sources.
May simplify apicoaortic bypass anastomosis; leaves open need for safety and outcome validation.
The proximal anastomosis of the apicoarotic bypass is technically demanding. We describe our novel surgical technique to reinforce the proximal anastomosis of the apicoaortic bypass. After moving circular muscle of the left ventricle (LV) under ventricular fibrillation, an inverted tube graft is inserted into LV through the opening of the apex. Then, end-to-end anastomosis is made with horizontal mattress sutures passing from the inside of the inverted tube graft through the entire thickness of LV muscle and a running suture of the edge of LV muscle and graft. As the tube graft is pulled out from the LV, the anastomosis is completed. This technique permits simple and reliable suture placement without the need for any special device for the proximal anastomosis of the apicoaortic bypass.
No takes yet. Share an insight, caveat, or question.
Nakamura et al. (2010) studied Apicoaortic bypass. Inverted graft insertion technique was evaluated. An inverted graft insertion technique for apicoaortic bypass permits simple and reliable suture placement without the need for any special device for the proximal anastomosis.