This article revisits fundamentals of Fabry–Pérot cavities, addressing limits of extreme miniaturization and consequences. More specifically, both the spectral responses and the mode profiles are found to be gradually affected by the size reduction of the cavity mirrors with respect to spot size of an incident optical Gaussian beam. A fully analytical methodology accounting for the finite borders of the cavity is proposed to predict the behavior. Severe consequences of miniaturization appear on the spectral response and in the spatial distribution of the resonant modes, with degradation of the quality factors, typically down to 665 for mirrors of 77 × 150 μm, while it should be 2407 for their macroscopic counterparts of equivalent cavity length of 210 μm and reflectance R = 70%. The observed deviations from the well‐established Fabry–Perot models are quantified and ascribed to imperfect mode confinement due to the finite mirror's dimensions. Validation of the modeling approach is given by comparing with experimental data obtained on microfabricated silicon cavities and another comparison with asymptotic values where analytical equations still apply. This work aims contributing to better assessment of microscale cavities used in photothermal and photoacoustic spectroscopy, in optofluidic devices for refractometry, biochemical, and gas sensing.