Key result
The combination of veno-arterial extracorporeal membrane oxygenation and intra-aortic balloon pump successfully stabilized hemodynamics and led to recovery in a 20-year-old male with refractory cardiogenic shock due to aluminum phosphide poisoning.
Why the study?
Acute toxic myocardial damage can cause cardiogenic shock with unacceptably high mortality, and specific antidotes are lacking for many toxins.
Case Report (n=1)
No
Answers are grounded in this paper and cite their sources.
May support combined mechanical circulatory support in rare refractory cardiogenic shock; leaves open prospective validation for aluminum phosphide poisoning.
Background: Acute toxic myocardial damage may be accompanied by the development of cardiogenic shock (CS), the mortality from which is still unacceptably high. Since there is no specific antidote for many types of toxins, treatment of such patients includes various measures of hemodynamic and respiratory support. The paper presents a case of refractory CS due to possible aluminum phosphide (AP) poisoning. Case summary: A 20-year-old man was admitted to the emergency department 4 days after home inhalation of AP due to complaints of nausea, vomiting, abdominal and chest pain. Over the next few hours, he rapidly developed CS, which was refractory to conservative treatment. Therefore, veno-arterial membrane oxygenation (VA-ECMO) was performed, during which hemodynamics stabilized, but later there were signs of left ventricular overload. To unload the left ventricle (LV), an intra-aortic balloon pump (IABP) was implanted, which significantly improved the patient's condition. After 6 days the patient was decannulated, and a few more days later IABP was discontinued. Subsequently, the patient was treated for sepsis due to bilateral pneumonia and acute respiratory distress syndrome and optimal medical therapy for heart failure was prescribed. The patient was discharged after 34th day of hospitalization.
No takes yet. Share an insight, caveat, or question.
Dukhin et al. (2023) conducted a case report in Refractory cardiogenic shock due to aluminum phosphide poisoning (n=1). Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and intra-aortic balloon pump (IABP) was evaluated on Clinical recovery and survival. The combination of veno-arterial extracorporeal membrane oxygenation and intra-aortic balloon pump successfully stabilized hemodynamics and led to recovery in a 20-year-old male with refractory cardiogenic shock due to aluminum phosphide poisoning.