We report about the design and test of an image processing algorithm for the localization of the optic disk (OD) in low-resolution (about 20 micro/pixel) color fundus images. The design relies on the combination of two procedures: 1) a Hausdorff-based template matching technique on edge map, guided by 2) a pyramidal decomposition for large scale object tracking. The two approaches are tested against a database of 40 images of various visual quality and retinal pigmentation, as well as of normal and small pupils. An average error of 7% on OD center positioning is reached with no false detection. In addition, a confidence level is associated to the final detection that indicates the "level of difficulty" the detector has to identify the OD position and shape.
No takes yet. Share an insight, caveat, or question.
Lalonde et al. (2001) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: