Key result
Second harmonic generation imaging and biaxial testing revealed layer-specific collagen orientation in human menisci, which was accurately represented by an anisotropic hyperelastic material model (mean r2 = 0.92).
Why the study?
To examine region- and layer-specific collagen fiber morphology and suggest a structure-based constitutive model for human meniscal tissue.
Effect estimate: r2 = 0.92
This study provides a region- and layer-specific constitutive model of human meniscal tissue based on SHG imaging and biaxial testing, which can improve surgical simulations and meniscal prostheses design.
Region-specific collagen data enable structure-based meniscal models; leaves open in vivo validation before clinical translation.
In this paper, we examine the region- and layer-specific collagen fiber morphology via second harmonic generation (SHG) in combination with planar biaxial tension testing to suggest a structure-based constitutive model for the human meniscal tissue. Five lateral and four medial menisci were utilized, with samples excised across the thickness from the anterior, mid-body, and posterior regions of each meniscus. An optical clearing protocol enhanced the scan depth. SHG imaging revealed that the top samples consisted of randomly oriented fibers with a mean fiber orientation of 43.3 o . The bottom samples were dominated by circumferentially organized fibers, with a mean orientation of 9.5 o . Biaxial testing revealed a clear anisotropic response, with the circumferential direction being stiffer than the radial direction. The bottom samples from the anterior region of the medial menisci exhibited higher circumferential elastic modulus with a mean value of 21 MPa. The data from the two testing protocols were combined to characterize the tissue with an anisotropic hyperelastic material model based on the generalized structure tensor approach. The model showed good agreement in representing the material anisotropy with a mean r 2 = 0.92.
No takes yet. Share an insight, caveat, or question.
Rasheed et al. (2023) studied Cadaveric human menisci (n=9). Second harmonic generation (SHG) imaging and biaxial testing was evaluated on Constitutive model fit for material anisotropy (r2 = 0.92). Second harmonic generation imaging and biaxial testing revealed layer-specific collagen orientation in human menisci, which was accurately represented by an anisotropic hyperelastic material model (mean r2 = 0.92).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: