Key result
Left ventricular guidewire pacing cuts TAVR procedural time by ~10 minutes vs. right ventricular pacing.
Why the study?
Intraprocedural rapid-pacing techniques during TAVR have lagged behind minimalist approaches, prompting the need to outline best practices for left ventricular guidewire pacing.
Does left ventricular guidewire rapid pacing improve procedural efficiency and safety compared to traditional right ventricular pacing in patients undergoing TAVR?
Does left ventricular guidewire rapid pacing improve procedural efficiency and safety compared to traditional right ventricular pacing in patients undergoing TAVR?
Left ventricular guidewire pacing is a safe, efficient, and cost-effective 'minimalist' strategy for temporary rapid pacing during TAVR.
Answers are grounded in this paper and cite their sources.
LV guidewire pacing may shorten TAVR time with comparable safety; leaves open need for randomized confirmation before practice change.
Transcatheter aortic valve replacement (TAVR) is continually evolving, with a recent emphasis on a "minimalist" approach toward reducing procedural invasiveness, duration, and recovery time. Whereas a better understanding of the relationship between TAVR and new conduction disturbances has led to improved periprocedural management, intraprocedural rapid-pacing techniques have not evolved beyond traditional right ventricular temporary pacing. An alternative strategy utilizing the left ventricular guidewire for rapid pacing has been developed with evidence supporting its safety, effectiveness, and potential reductions in procedure time and cost. This review will outline the current best practices in left ventricular pacing for TAVR, a practical technique that embraces the minimalist approach to TAVR and may be considered for routine use. It aims to explore the current evidence and combine this with expert opinion to offer a strategy for temporary pacing that encourages efficiencies for physicians and patients without compromising periprocedural safety.
No takes yet. Share an insight, caveat, or question.
Blusztein et al. (2023) conducted a review in Transcatheter aortic valve replacement (TAVR). Left ventricular guidewire rapid pacing vs. Right ventricular temporary pacing was evaluated. Left ventricular guidewire rapid pacing during TAVR reduces procedural time by 7-13 minutes compared to traditional right ventricular pacing while maintaining similar safety and efficacy.
Synapse has enriched 10 related papers. Consider them for comparative context: